background image

Recall Shortcut

•  Press the right POWER   button to activate the SOLDERING STATION.

•  Press and hold the right POWER   button together with a shortcut button (12, or 3) to 

recall a shortcut.

•  The LCD display (9) will indicate the actual temperature “REAL”. 

e) Temperature Compensation/Calibration  

•  Press and hold the right POWER   button and the   button on the hot air gun handle (1).

•  The LCD display (9) will begin to blink and show “CAL”.

 - Press UP or DOWN on the control panel (15).

 - Press UP or DOWN using the hot air gun controls (2).

  Press and hold UP or DOWN to rapidly adjust 

values.

•  Press SET on the control panel (15) to save the setting.

Replacing the fuse

  Allow the hot air gun and soldering iron to cool down completely, then turn the main 

power switch OFF (7) and disconnect the power cord from the socket (14).

•  Remove the cover over the fuse holder (13) located at the back of the main unit.

•  Use a blunt object such as a flat head screwdriver to gently pry the fuse out. 

•  Perform a continuity test on the fuse, e.g. with an appropriate meter (digital multimeter). 

•  If the fuse is defective, replace it with a new fuse of the same type (see “Technical data” at 

the end of these operating instructions).

  Never use a fuse with other specifications. Never bridge a defective fuse! This may 

cause a fire or a fatal electric shock!

•  Insert a replacement fuse until it clicks into place, then replace the protective cover.

•  Connect the workstation to the mains and switch it back on.

  If  the  fuse  blows  again,  disconnect  the  workstation  from  the  mains  and  ask  a 

technician to conduct a thorough inspection.

Troubleshooting

a) Soldering Iron

LCD

Error Message/ 

Fault Indication

Suggestions

There is no 

temperature reading.

Please contact technical support 

service or other technical 

personnel.

The maximum 

temperature was 

exceeded. 

Reduce the set temperature.

Switch the main power OFF, wait 

20 minutes then turn back ON

Please contact technical support 

service or other technical 

personnel.

b) Hot Air Gun

LCD

Error Message/Fault 

Indication

Suggestion

There is no 

temperature reading.

Please contact technical support 

service or other technical 

personnel.

The maximum 

temperature was 

exceeded. 

•  Reduce the temperature 

setting.

•  Switch the main power OFF

wait 20 minutes then turn 

back ON

•  If still receive the error code, 

please contact technical 

support service or other 

technical personnel.

Care and Cleaning

a) Main Unit and Hot Air Gun

•  These are generally maintenance free. Disconnect the product from the mains, and allow all 

parts to cool down completely before each cleaning.

•  Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as 

they can cause damage to the housing and malfunctioning.

•  Clean the product with a dry, fibre-free cloth.

b) Soldering Iron

•  Always keep the tip tinned before switching off or storing for any period of time. 

•  Never clean the tip with coarse, abrasive materials like files.

•  If oxide forms on the tip, lightly rub with abrasive paper, wipe clean, then immediately reheat 

and re-tin the tip to prevent oxidation of the wettable surface.

Disposal

  Electronic  devices  are  recyclable  waste  and  must  not  be  disposed  of  in  the 

household waste. At the end of its service life, dispose of the product in accordance 

with applicable regulatory guidelines.

 

You  thus  fulfill  your  statutory  obligations  and  contribute  to  the  protection  of  the 

environment.

Technical Data

a) Main Unit

Input voltage ................................. 230 V/AC, 50 Hz,
Power consumption ...................... max. 700 W
Fuse .............................................. T5A (230 V/AC)
Operating conditions ..................... 0 to 40 ºC, 0 - 80 % RH (non-condensing)
Storage conditions ........................ -20 to +80 ºC, 0 - 80 % RH (non-condensing)
Power cable ..................................  Length: approx.140 cm (without connector and plug)
Dimensions (W x H x D) ...............  186 x 169 x 255 mm (without hot air gun holder)
Weight ..........................................  4252 g (main unit with hot air gun and holder) 

b) Soldering Iron

Power consumption ...................... 50 W
Temperature range ....................... approx. 200 °C to 480 °C
Temperature accuracy .................. ±10 °C
Temperature offset ........................ ±50 °C
Temperature stability .................... ±2 °C
Tip to ground impedance .............. <2 Ω
Tip to ground voltage .................... <2 mV
Cable length ................................. 90 cm
Dimensions (ø x H) ....................... approx. 24 x 185 mm
Weight .......................................... 105 g

c) Soldering Iron Holder

Dimensions (W x H x D) ............... 71 x 84 x 155 mm
Weight .......................................... 260 g

d) Hot Air Gun

Power consumption ......................

550 W

Temperature range ....................... approx. 100 °C to 500 °C
Temperature accuracy .................. ±35 °C
Temperature stability .................... ±5 °C
Maximum airflow ........................... 23 L/min
Pump type .................................... Diaphragm
Nozzle tips ....................................  (QFP) quad flat pack:10 x 10 mm 

(QFP) quad flat pack:14 x 14 mm 

Round: ø4 mm 

Round: ø8 mm

Dimensions (Ø x H) ...................... 44 x 195 mm
Weight .......................................... 230 g
Cable length ................................. 90 cm

  Visit the Conrad website and search Item No.: 2108712 for information about any 

optional accessories, spares, or replacement parts.

This  is  a  publication  by  Conrad  Electronic  SE,  Klaus-Conrad-Str.  1,  D-92240  Hirschau  (www.conrad.com). All  rights 

including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication 

represent the technical status at the time of printing.
Copyright 2019 by Conrad Electronic SE. 

*2108712_v1_0919_02_dh_m_en

Содержание 2108712

Страница 1: ...n elektrischen Komponenten oder Bauteilen durch die unter Spannung stehen Trennen Sie solche Komponenten vorher stets von der Stromversorgung Achtung Sollte es einmal vorkommen dass Flüssigkeit in die SMD Lötstation gelangt ist schalten Sie immer zuerst die Netzspannung zur Netzsteckdose ab an der die Lötstation angeschlossen ist Sie müssen den zugehörigen Leitungsschutzschalter abschalten bzw die...

Страница 2: ... 7 Hauptschalter ON OFF 8 LC Display SMD REWORK 9 LC Display SOLDERING STATION 10 Lötkolbenhalterung 11 Eingangsbuchse für Lötkolben 12 Schwamm 13 Sicherungshalterung 14 Netzanschluss 15 Bedienfeld Anschluss und Aufstellung Stellen Sie sicher dass sich der Hauptschalter in der OFF Position befindet und das Netzkabel noch nicht an die Stromversorgung angeschlossen ist Die Halterung der Heißluftpist...

Страница 3: ...der Halterung 3 befindet und sie schaltet sich aus wenn die Temperatur unter 100 C fällt Das Hauptgerät wechselt dann in den Ruhemodus und auf dem LC Display 8 wird SLP angezeigt SLP Ruhe Standby Modus SET Eingestellte Temperatur REAL Tatsächliche Temperatur b Außerbetriebsetzung Um Schäden am Produkt zu vermeiden lässt sich das Hauptgerät erst dann mit dem Hauptschalter 7 AUSSCHALTEN wenn die Tem...

Страница 4: ...n Sie den eingestellten Temperaturwert Schalten Sie die Stromversorgung des Geräts AUS warten Sie 20 Minuten und schalten Sie sie wieder EIN Sollte die Fehlermeldung weiterhin angezeigt werden wenden Sie sich an unseren technischen Kundendienst oder anderes Fachpersonal Pflege und Reinigung a Hauptgerät und Heißluftpistole Beide sind in der Regel wartungsfrei Trennen Sie das Produkt vor der Durchf...

Страница 5: ... supply beforehand Caution If liquid does enter the workstation switch off the mains voltage to the socket containing the mains plug switch off at the corresponding circuit breaker or remove the safety fuse and then switch off at the corresponding RCD protective switch You can then unplug the power adapter from the mains socket Discontinue use immediately and take the product to a specialist repai...

Страница 6: ... 1 Hot air gun handle 2 Hot air gun controls 3 Hot air gun holder 4 Hot air gun nozzle 5 Main unit carry handle 6 Soldering iron handle 7 Main power switch ON OFF 8 LCD display SMD REWORK 9 LCD display SOLDERING STATION 10 Soldering iron holder 11 Soldering iron input socket 12 Sponge 13 Fuse holder 14 Power socket 15 Control panel Connection and Setup The power switch should be in the OFF positio...

Страница 7: ...n 5 seconds to assign a shortcut The temperature will appear on the LCD 9 above the corresponding shortcut button to indicate it has been assigned SMD REWORK STATION a Power On Turn the main power switch ON 7 On the control panel 15 press the left POWER button to activate the SMD REWORK STATION The hot air gun will start heating up when the handle 1 is removed from the holder 3 The hot air gun wil...

Страница 8: ...e Disconnect the product from the mains and allow all parts to cool down completely before each cleaning Do not use any aggressive cleaning agents rubbing alcohol or other chemical solutions as they can cause damage to the housing and malfunctioning Clean the product with a dry fibre free cloth b Soldering Iron Always keep the tip tinned before switching off or storing for any period of time Never...

Отзывы: