TOOL KLEAN TK-1-SSRTT Скачать руководство пользователя страница 4

All Tool Klean products are assembled, tested, and
inspected at our New York EPA facility and are compliant
with US laws & regulations.  If you have an issue with one of
our products, please contact Technical Support at 800- 706-
1677 or email [email protected]
If the tabletop does not turn on - unplug the unit, wait 5
seconds, plug directly into a wall outlet to reset. Do not use
power strips. Heavy gauge extension cords can be used. If
the reset is unsuccessful contact Technical Support. 
If the tabletop turns on, but the bulb does not turn on - try to
reset the unit. If the reset is unsuccessful, change the bulb
and try again (See directions to change the bulb). If the
reset is still unsuccessful contact Technical Support.
If the tabletop starts, but the bulb flickers, reset the unit.
Note: fluorescent bulbs take time to start as the ballast
warms up. If a restart is unsuccessful, change the bulb. If
the reset is unsuccessful contact Technical Support.
Bulbs may appear darker in color closer to the ends near
the filaments, this is normal.  However, if the bulb does not
emit light from the center of the bulb, change the bulb.  If
this is unsuccessful contact Technical Support.
If the bulb does not stay on during timed treatment, reset
the unit. If the bulb still does not stay on during treatment,
change the bulb. If neither option works, contact technical
support.  
If the timer does not work, re-sync your remote. If this is
unsuccessful, change the battery.  If the reset is
unsuccessful contact Technical Support.

TROUBLESHOOTING:
 

 

TO CHANGE THE BULB:

TO SYNC YOUR REMOTE TO THE TABLETOP:

1. Press and hold the 30 minute button on the base of the
tabletop. With the other hand plug the unit into a wall socket.
You will hear a beep and see a green light appear on the base.
Unplug and release the 30 min. button. 
2. Next press the 60 minute button on the remote and
simultaneously press and hold the 60 min button on the base
of the tabletop. With the other hand plug into a wall socket. The
base will beep and a green light will appear. 
3. Pull the plug and release the 60 minute button on both the
remote and base. Test the remote syncing by pressing each
button separately and waiting for the beep sound. 
4. If the remote is still not synced, repeat the process 1-2 more
times / See service video on remote syncing on
https://toolklean.com/pages/product-videos-and-manuals

1. Unplug the tabletop from the power source. 
2. Unscrew the four screws at the base of the unit and pull the
top of the tabletop upward 1/2 way, exposing the black rubber
bulb protector. 
3. Remove the rubber bulb protector and finish removing the top. 
4. Unscrew the two screws connecting the bulb to the base and
carefully pull up to expose the wiring. 
5. Carefully unplug the wire from the bulb. 
6. Plug in the new bulb and screw the bulb base to the tabletop
base.  
7. Carefully slide the top back on 1/2 way and re-insert the
rubber bulb protector. 
8. Slide top all the way down to the base. 
9. Screw the top back on to the base. 
10. Test bulb and remote as per instructions in the OPERATION
section on page 2. See the service video on how to change the
bulb on https://toolklean.com/pages/product-videos-and-
manuals

Page 4 - Troubleshoot, Change bulb, Sync Remote

Отзывы: