70
Period
ACV
Range
Frequency
Range
Resolution
Full Scale
Reading
Accuracy
(2)
Input Sensitivity
(Sine Wave)
100mV
to
750V
1~10μs
(1)
10μs~10ms
10ms~100ms
100ms~200ms
0.1ns
1ns
1μs
10μs
9.9999
9.9999
99.999
199.99
0.01
%
+0.008
%
0.01
%
+0.008
%
0.01
%
+0.02
%
0.05
%
+0.02
%
500mV rms
300mV rms
300mV rms
200mV rms
Maximum Crest factor: 3.0 at full scale
Maximum input voltage: 750Vrms
≤3×10
7
Volt-Hz for all ranges
Input impedance: 1MΩ±2% in parallel with capacitance <100pF
Maximum DCV: 500V for all AC ranges
Triggering and Memory
Reading hold sensitivity: 0.01%, 0.1%, 1% or 10% of reading
Math Functions
Rel, Max/Min, dBm, dB, Compare Limit Test and %
dBm Reference Resistance: 1Ω to 9999Ω (1Ω step size), default is 75Ω
Standard Programming Languages
SCPI
(
Standard Commands for Programmable Instruments
)
Remote Interface
RS-232C
General Specifications
Power Supply: 110/220V±10%
Power Line Frequency: 50/60Hz ±5%
Power Consumption: ≤
10VA
Operating Environment: 0
℃
to 40
℃
, ≤90%RH
,
Storage Environment: -40
℃
to 70
℃
Warm-up: more than 30mins
Dimensions (W×H×D): 225mm
×
100mm
×
355mm
Net Weight: Around 2.5Kg
Warranty: 2 years