![Tone Power Digitorqon PDX-301F Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/tone/power-digitorqon-pdx-301f/power-digitorqon-pdx-301f_instruction-manual_1126260049.webp)
- 48 -
8-7-4. Turn ON/OFF Auto Start Mode
In the auto start mode, tightening torque measurement starts automatically as the
variation in tightening torque is detected.
Advantage and Disadvantage of Auto Start Mode
OFF
ON
Pressing Button
Press SET ● button
before measurement
Not necessary
Zero Adjustment
Upon turning on the
power,
or
at
every
measurement
Upon turning on the power, or
only when pressing SET ●
button.
Battery Life
Complying
with Specifications
Depending on usage condition
①On
“
Menu screen
”
(Page.26), display and scroll
the 4th menu.
indicates that auto
start mode is currently OFF.
indicates that auto
start mode is currently ON..
② Press
SET●
to run the displayed menu.
③ The current mode is displayed.
●
CAUTION When the torque measurement is started with the auto start mode ON ,
tightening torque will be measured with reference to “Zero adjustment” performed
immediately after power ON, or to “Zero adjustment” performed upon displaying the
previously measured peak torque value by pressing SET● button. If “Zero adjustment”
has not been made for a long time, press SET● button and manually perform “Zero
adjustment”
CAUTION The ON / OFF setting data of auto start mode will be stored and
retained after turning off the power.