![Tone Power Digitorqon PDX-301F Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/tone/power-digitorqon-pdx-301f/power-digitorqon-pdx-301f_instruction-manual_1126260033.webp)
- 32 -
CAUTION
● Graduation on the torque setting dial is only a rough guidance.
□
Tightening torque varies depending on tightening condition.
□
It is recommended to adjust torque setting dial each day before
operation or whenever tightening condition is changed.
● Gradually adjust torque setting dial from low torque to high
torque to prevent over loading.
6-5. Tightening Operation
NOTE This section describes operating procedure in the auto start OFF mode.
Refer page 49-51 for auto start ON/OFF
NOTE Measured torque will only be stored in the microSD memory card when it is
correctly inserted into the slot.
Squeeze trigger switch to activate
the wrench only when window
displays
2. As tightening proceed, display reads actual tightening torque until wrench stops
automatically. Peak hold torque value will appear on the display.
CAUTION
● Target torque will not be obtained if trigger switch is released
before the wrench stops automatically
50
× 1 0 0
N m
40
20
30
Trigger Switch