![Tomura DVR5216-A Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/tomura/dvr5216-a/dvr5216-a_user-manual_1126166047.webp)
47
DVR
Enter “Motion detection” interface by “Main Menu” -> “Alarm Setup” -> “Motion” as below:
You can judge if the scene have any changes by checking the realtime record. If you want to record when there have someone or something moving in channel scene, you can set “Motion
Detection” to record. User can set motion alarm record time, deploy time, sensitivity, motion detection area and alarm output channel.
Motion detection operation steps:
Step1: Enter “Main Menu” -> “Record Setup” -> “Record para.” interface to set corresponding channel pre-record time and delay-record time.
Step2: Select the channel number which you want to motion record.
Step3: Continuous alarm: after enable, motion alarm will continuous alarm when there has something moved in the video image.
Step4: Define the motion detection sensitivity level: There have 5 levels: 1(lowest level )~5(Highest level). When the system detect that have motion in the scene, it will alarm and
motion record. If you choose low sensitivity, such as 1, it will alarm only when there has big change in the channel scene. If choose 5, if there have little change in the channel scene,
it will motion alarm.
Step5: Detection area setting: Yellow color will detect motion. Grey color will not detect. System default the whole area will detect.
Set motion area by remote controller or by DVR front panel: Press direction key to move the cursor to make sure the start point. Press “OK” button to select, only can select a grid one
by one. Press “Return” button return to motion detection interface to save the setting.
Set motion area by mouse: Left click mouse to select one start point, drag mouse to other place, then loose the mouse, it will display a area box. This area is the motion detection area.
Right click mouse to return pre-interface. Double left click mouse to cancel the motion area setting.
Step6: Set the deployment time (the specific setting please refer to schedule record).
Step7: Linkage setting: Set Trigger Record, Screenshot linkage, Alarm output, Email linkage, PTZ preset point.
4.6 Alarm Setup
“Alarm Setup” interface is as right:
Note: In this part, some model don’t support alarm (sensor alarm,
alarm output, manual alarm), please refer to actual situation.
4.6.1 Motion
Содержание DVR5216-A
Страница 23: ...23 DVR 3 5 IR Remote Controller Operation ...