background image

3

THIS FAN IS SUITABLE FOR DAMP LOCATIONS SUCH AS

COVERED PORCHES, COVERED PATIOS, AND COVERED DECKS...

ANYWHERE THERE IS A ROOF OVERHEAD.

Tools Needed for Assembly

One Phillips head screwdriver
One wire stripper
One stepladder
One 5/32Ó hex wrench (supplied)
Four wire connectors (supplied)

Materials

Wiring, outlet box and box connec-
tors must be of type required by the
local code. The minimum wire would
be a 3-conductor (2-wire with
ground) of the following sizes:

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Installed Wire Length Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

Before assembling your ceiling fan,
refer to section on proper method of
wiring your fan (page 9). If you feel you
do not have enough wiring knowledge
or experience, have your fan installed
by a licensed electrician.

!

WARNING

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each
step is completed, place a check mark in the box. This will insure that all
steps have been completed and will be helpful in finding your place should
you be interrupted.

Do not install or use fan if any part is
damaged or missing. Call Toll-Free:

1-800-654-3545

!

WARNING

This product is designed to use only
those parts supplied with this product
and/or any accessories designated
specifically for use with this product by
Emerson Electric Co. Substitution of
parts or accessories not designated for
use with this product by Emerson
Electric Co. could result in personal
injury or property damage.

!

WARNING

1. Open styrofoam unit containing

fan. Remove top half of styrofoam
unit. Remove parts and check to
see that you have received the fol-
lowing parts:

NOTE: If you are uncertain of part
description, refer to exploded view
illustration.

a. Fan motor and housing assembly
b. One ceiling cover
c. One motor cover
d. Five blade flanges
e. One hanger bracket
f. One hanger ball/downrod assembly
g. One switch housing cover

BP7289 Tommy Bahama TB344  2/26/09  10:11 AM  Page 3

Содержание BAHAMA BREEZES

Страница 1: ...XXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Net Weight 19 0 Lbs Part No F40BP728900001 Form No BP7289 1 READ...

Страница 2: ...y U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not accept able for f...

Страница 3: ...check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place sho...

Страница 4: ...s 11 One clevis pin hairpin clip assembly C H E A G D F B Electrical Requirements 12 Eleven 10 32 x 3 4 oval head screws 13 Twenty one 10 32 x 5 16 Phillips pan head screws 14 Twenty one 10 flat washe...

Страница 5: ...itter There are no controls supplied with the ceiling fan How to Assemble Your Ceiling Fan 4 Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and s...

Страница 6: ...rly installed as shown in Figure 2 could result in the fan falling WARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify th...

Страница 7: ...lade flange align with the two round To reduce the risk of personal injury do not bend the blade flanges when installing the flanges balancing the blades or cleaning the fan Do not insert foreign obje...

Страница 8: ...sed for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Hanger bracket must seat firmly against outlet box...

Страница 9: ...ntrol Receiver or Wall Control Receiver to oper ate your ceiling fan wire your fan in accordance with the Control Receiver Owner s Manual After wiring return to step 4 a Connect the green grounding le...

Страница 10: ...green colored insulation Securely connect wires with a wire connector supplied b Securely connect the fan motor white wire to the sup ply white neutral wire using a wire connector supplied c Securely...

Страница 11: ...ING Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electrici ty on at the main fuse or circuit breaker box 2 Check the operation of the fan by gently pulling on the...

Страница 12: ...o install a Tommy Bahama accesso ry light kit remove the two screws securing the switch housing cover on the switch housing Remove the threaded plug from the switch hous ing cover and install the ligh...

Страница 13: ...ousing screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling 1 Raise coupling cover and excessively is not tightened securely tighten setscrew securely 2 Setscrew...

Страница 14: ...all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your...

Страница 15: ...x 3 4 11 16 Screw Pan Head 8 32 x 3 8 2 17 Pendant Hibiscus 18 Pendant Bell 19 Coupling 2 20 Cover Ceiling 762768 AP 762768 BBR 762768 CW 762768 DBZ 21 Cover Motor 762769 AP 762769 BBR 762769 CW 7627...

Страница 16: ...charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What...

Отзывы: