9.
All other error codes. Turn off the main power switch and disconnect the positve battery cable from the
batteries for more than one minute (the time is needed to drain the controller's on-board capacitor).
Reconnect the cables being sure they are tight; too loose will burn the batteries. If you overtighten the cables
you can damage the battery's lead terminal. Try again.
10.
If the problem cannot be solved by any of these remedie's call your local dealer's service department.
5. 7900 AND 7901 ERROR.
The emergency stop button
is out.
6. HIGH THROTTLE ERROR.
You pressed the drive button
before turning on the key. Turn off the key, release
the drive button and try again.
7. 2C00 AND 2C01 ERROR.
Low voltage warning.
Voltage has dropped down below the minimum
required to operate the machine. If you wait a few
minutes, the batteries may coast up a bit in voltage,
allowing you to drive very slowly to the recharge
station.
8. 7802 ERROR.
The traction motor was used to climb
a ramp, and was running up the ramp for more than
the 60 seconds allowed for this. Turn off the key, turn
on again, and continue. You should not use this
machine to climb ramps so steep and so long that this
code comes up repeatedly, or you could overheat
and damage the traction motor.
TROUBLESHOOTING CENTRAL COMMAND
PAGE 30