- 10 -
EDGESTICK-OP-EN
MOTOR INFORMATION
There is a sticker with the above information on the motor of your EDGE Stick machine unit. Below are explana-
tions for the units of measurement.
FLA = Full Load Ampere Rating
Line current drawn by motor while operating under full load at supply voltage indicated. On dual voltage motors, higher
voltage amps are one-half lower voltage amps.
SFA = Service Factor Amps
Current drawn by the motor when operated at service factor load. Unless motor is operated extensively at service factor
load (not recommended), use full load current when selecting circuit protection.
SF = Service Factor
The service factor shown on the motor nameplate indicates the amount of continuous overload the motor can be subject-
ed to, under nameplate conditions, without damaging the motor. When the voltage and frequency are at the same values
as shown on the motor nameplate, the motor may be overloaded up to the horsepower indicated by multiplying the rated
horsepower by the service factor. When operated at service factor load, the motor may have an effi ciency, power factor,
and speed slightly different from those shown on the nameplate.
A motor designed to operate at its nameplate horsepower rating has a service factor of 1.0. This means the motor can
operate at 100% of its rated horsepower. Some applications may require a motor to exceed the rated horsepower. In these
cases a motor with a service factor of 1.15 can be specifi ed. The service factor is a multiplier that may be applied to the
rated power. A 1.15 service factor motor can be operated 15% higher than the motor’s nameplate horsepower. The 30
HP motor with a 1.15 service factor, for example can be operated at 34.5 HP. It should be noted that any motor operating
continuously at a service factor greater than 1 will have a reduced life expectancy compared to operating it at its rated
horsepower. In addition, performance characteristics, such as full load RPM and full load current, will be affected.
EF = Effi ciency Factor
AC motor effi ciency is expressed as a percentage. It is an indication of how much input electrical energy is converted to
output mechanical energy. The nominal effi ciency of this motor is 93.6%. The higher the percentage the more effi ciently
the motor converts the incoming electrical power to mechanical horsepower. A 30 HP motor with a 93.6% effi ciency would
consume less energy than a 30 HP motor with an effi ciency rating of 83%. This can mean a signifi cant savings in energy
cost. Lower operating temperature, longer life, and lower noise levels are typical benefi ts of high effi ciency motors.
FLPF = Full Load Power Factor
The ratio of real or true power and the apparent power that is supplied [PF=P(watts)/S(va)]
IEC34-1
IEC34-5
MODEL: M6K28FC3A
CAT. NO: 117536.00
DATE: G12B
TYPE: KF
ENCL: TEFC
DESIGN:l
HP/KW: 1 1/2 / 1.12
1 1/2 / 1.12
RPM:
VOLT:
FLA:
13.2/6.6
15.6/7.8-7.5
SFA:
14.8/17.4
18/9-8.4
SF:1.15
NP,BF1461412-1,122060009
READ WARNING LABEL ON MOTOR BEFORE
CONNECTING, INSTALLING OR SERVICING
FAILURE TO FOLLOW ALL SAFETY INFORMATION
CAN RESULT IN PERSONAL INJURY OR DEATH.
EFF:75.5
IP:
:41
:
:
:
:
FL PF:99(0.99)
115/230
100/200-220
3450
2850
HZ:
60
50
CC:
CUST: PN:
DUTY:CONT
INS:F4
PH:1
CODE:H
FR:56CZ
THERMALLY PROTECTED
AMB:40 C
LOW VOLTAGE
CCW ROTATION FACING LEAD END AS SHOWN
INTERCHANGE LEADS T5 & T8 FOR CW
HIGH VOLTAGE
P1 P2 T3 TB T2 T4 T5
P1 P2 T3 TB T2 T4 T5
COOLING
CODE
INVERTER
SPD RANGE
PROT.
CODE
INV
TYPE
INV.
LOAD
L1
L2
L1
L2
E57948
LR33543
®
®