background image

EN

 

       

 

USER INSTRUCTION   

 

TOM02I  (HYBIRD series)

Page  5

 

 

Fig. C

Min. 20 mm

Min. 30 mm

F

OVEN WITH

COOLING FAN

Min. 20 mm

Min. 30 mm

G

NO DRAWER ALLOWED

UNDER THE INDUCTION MODULE

Min. 5 mm

57,50

53,6

DETALLE F 

ESCALA 1 : 6

Min. 5 mm

DETALLE G 

ESCALA 1 : 6

SECURITY DISTANCES WITH FURNITURE

 

A -  ON/OFF key

 > 

switch the appliance on and off

B -  Timer Plus key

 > 

increase timer value 

(OPTIONAL)

C -  Timer Minus key

 > 

decrease timer value 

(OPTIONAL)

D -  Lock key

 > 

activate control panel lock /child lock

  

 

E -  Plus key

 > 

increase power level of cooking zone

F -   Minus key 

reduce power level of cooking zone

Fig. D  Touch control Guide

A

B

C

D

E

F

E

F

E

F

E

F

EN

 

       

 

USER INSTRUCTION   

 

TOM04I-P (PANORAMIC series)

Содержание TOM04I-P

Страница 1: ...Tomate eco friendly efficiency INDUCTION MODEL TOM04I P PANORAMIC series MANUAL USER www tomate com vn ...

Страница 2: ...ATER 12 7 POWER MANAGEMENT 12 8 KEY LOCK 12 PART A GENERAL INFORMATION QUICK GUIDE 3 4 5 6 PART B INSTRUCTIONS EN USER INSTRUCTION TOM04I P PANORAMIC series 9 AUTOMATIC SAFETY OFF 15 10 OPERATING THE TIMER 16 10 1 ACTIVATING THE TIMER 16 10 2 SELECTING A TIMED HEATER 16 10 3 SELECTING THE TIME 16 10 4 STARTING TIMER COUNTDOWN 17 10 5 CHANGING THE TIME 17 10 6 TIMER COUNTDOWN END 18 10 7 SWITCHING ...

Страница 3: ...king area of the fibreglass top People carrying pacemakers are advised to consult a doctor before using the induction cooking areas Metal objects such as knives forks spoons or lids must not be placed on the surface of the cooking top because they can become hot IMPORTANT After use switch the cooking top off using the control device IMPORTANT Avoid spilling liquid therefore reduce the heat when bo...

Страница 4: ...imensions Fig B CAUTION THIS PRODUCT IS SENSIBLE TO ESD AND MUST BE MANIPULATED IN ELECTROSTATIC PROTECTED AREA EPA Brackets Fixing Points SelfTapping Screw 3 5x9 5 x4 B B FINAL ASSEMBLY 510 mm 770 mm 490 mm 750 mm Max 30 mm EN USER INSTRUCTION TOM04I P PANORAMIC series ...

Страница 5: ... ESCALA 1 6 SECURITY DISTANCES WITH FURNITURE A ON OFF key switch the appliance on and off B Timer Plus key increase timer value OPTIONAL C Timer Minus key decrease timer value OPTIONAL D Lock key activate control panel lock child lock E Plus key increase power level of cooking zone F Minus key reduce power level of cooking zone Fig D Touch control Guide A B C D E F E F E F E F EN USER INSTRUCTION...

Страница 6: ... Fig F Fig E Ⓐ Ⓑ H Fig The recipients must contain iron for induction heater COOKING RECIPIENTS CLEAN by suitable product or cloth paper TECHNICAL SPECIFICATIONS 1 2 3 4 Brown PE N PE N 1 Brown 3 4 2 a Fig G EN USER INSTRUCTION TOM04I P PANORAMIC series ...

Страница 7: ...he touch keys If during this calibration process excessive ambient lighting is detected the User Interface displays FL Infrared Ambient Light Error and the control calibration process is suspended In order to rectify the process any lighting that could effect the calibration process should be switched off e g halogen cooker hood lighting The error will disappear when satisfactory ambient lighting ...

Страница 8: ...e to an accidental activation of keys the touch control actuates as above Acoustic warning to attract the user s attention Pan detection for induction heaters After 60 sec with no pan the heater switches off GENERAL KEYS 1 key for switching On Off the Cooktop ON OFF 1 key for locking the keyboard KEYLOCK 2 key for timer time set TIMER TIMER HEATER KEYS 2 keys for each heater to select the cook set...

Страница 9: ...ater is not done in 10 seconds the Cooktop will be turned off automatically The Cooktop is switched OFF by touching the ON OFF key for 1 sec A beep sounds and all the heaters are switched off The ON OFF key will be locked to switch On the Cooktop if the key lock is activated KEYLOCK LED on or if there is any appliance error Fig 2 Switching OFF the cooktop Fig 1 Switching ON the cooktop EN USER INS...

Страница 10: ...e Induction Control Unit The keys will be locked o If the Cooktop is off or o if the key lock is activated KEYLOCK LED on or o if there is any heater error or appliance error If the finger is held down on the key the action is repeated twice every second The key raises the cooking level to 9 whereas the key reduces the cooking level to 0 With the heater at power level 0 the key raises the cooking ...

Страница 11: ...erface configuration has not specific keys for the Booster function With the heater at power level 9 the key raises the cooking level to Booster level a beep sounds and the heater display shows P With the heater at power level 9 the key raises the cooking level to Booster level a beep sounds and the heater display shows P With the heater at Booster level if the key is Touched an error beep sounds ...

Страница 12: ...NOTE The selectable power limits are 2800W 3500W or 6000W even if the cooktop maxi mum power is lower than 6000W 7 1 Setting Cooktop ECO Power Limit The sequence to set a new Cooktop Power Limit is During the first 30 seconds after plugging the appliance The Touch has to be unlocked and all Heaters Off Press at the same time the left and right end heaters and keys Once this is done a beep sounds a...

Страница 13: ...uence to finish recording the new Cooktop Power Limit is Press at the same time the left and right end heaters and keys Once this is done new Cooktop Power Limit is recorded and there is a system reset To finish without recording changes If during 60 seconds there is no action changes are not recorded and there is a system reset Fig 9 Selecting the Cooktop power limit Fig 10 Accepting the selected...

Страница 14: ...hing the KEYLOCK key for 1 second the key lock function is activated and deactivated If the LED associated to the key lock key is on the keyboard is locked The locking function can be activated when the heaters are on or when the cook top is off If the cook top is on the key lock function locks all the keys except the general ON OFF key and the KEYLOCK When the cook top is off the key lock functio...

Страница 15: ...omatic safety off If the power level is not changed during a preset time the corresponding heater turns off automatically The maximum time a heater can stay on depends on the selected cooking level Power level Max time on hours 1 10 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9 3 Table 1 Heater Auto switch off ...

Страница 16: ... When the timer off it is activated by pressing the timer keys TIMER or TIMER A beep sounds the timer display shows a 00 and the heater displays show a t blinking indicating that a heater has to be selected 10 2 Selecting a timed heater When the timer is waiting a heater selection the timed heater is selected by pressing any heater key A beep sounds the LED next to the heater display starts blinki...

Страница 17: ...d is increased automatically This makes possible to reach the desired time setting more quickly If the time is not selected before 10 seconds the timer is switched off If the selected time is 00 after 10 seconds the timer is switched off 10 4 Starting Timer Countdown The countdown starts 10 seconds after the last operation over the TIMER or TIMER key A beep sounds and the timer display stop blinki...

Страница 18: ...ed off 10 7 Switching off the timer To cancel the operation of the timer select the time value of 00 using the TIMER key or pressing the TIMER and TIMER keys at the same time 10 8 Autokey lock When all the heaters are not powered and one heater is temporized at zero power level the key lock function is activated after 1 minute Fig 17 Timer countdown end Fig 18 Timer off 11 Displaying software vers...

Страница 19: ...ey the right end heaters key and the Key Lock key A beep sounds and the rear heater displays show the software version Software version is composed of two parts functional part and safety part To distinguish between the two parts when safety version is shown the dots of the displays are activated The message is kept for 10 seconds or until any key or combination of keys is touched When the message...

Страница 20: ...O power limit 2 sec Power increment not allowed On Off r Heater without suitable pan or without pan No pan or not suitable pan over the heater Suitable pan over the heater After 1 minute Heater off On Power Induction heater overtemperature COIL TEMPERATURE T1 1 COIL TEMPERATURE T2 1 No power is delivered to the heater Off or H C On Power Induction generator overtemperature HEATSINK TEMPERATURE T3 ...

Страница 21: ... sec back 0 5 sec Communication fault When the fault disappears Left or right side heaters Off F5 Heater temperature sensor short circuit When the fault disappears Heater Off F1 Heater temperature sensor open circuit When the fault disappears Heater Off F2 Heater temperature sensor error 1 When the fault disappears Heater Off F7 Heater temperature sensor error 2 When the fault disappears Heater Of...

Страница 22: ......

Отзывы: