Doc# 16302
Press Pilot 150 Manual
Page 38
_
Message Code 28 & 128 – CLUTCH AIR PRESSURE FAULT
The PP150 is constantly checking to make sure the system has a good
signal from the clutch air pressure switch. Make sure the clutch air
pressure switch is set correctly in order for the PP150 to accurately
advise of incorrect pressure. Check the pressure switch, and press
the PP150 reset button to reset the fault.
FAULTS 31-38 and 131-138 ARE FAULTS EXCLUSIVE TO THE HARD
CAM BASED SYSTEM.
ALL CAM FAULTS CAN BE CAUSED BY FAULTY CONTACTS ON
SWITCHES THAT BOUNCE (Codes 31-38 and 131-138).
Message Code 31 & 131 – PROX CYCLED AND A CAM WAS ON
This fault means that the Prox check cycled while either Bcam or Tcam
was on. The prox in a Cam based system should always come on in the
top zone. Adjust the prox so that it does not cycle until Tcam is off,
but before Bcam comes on. Refer to Chapter 2 Section xiii for a
graphical illustration. Press the PP150 reset button to reset the
fault.
Message Code 32 & 132 – BCAM ON AND PROX DIDN’T CYCLE
The prox in a Cam based system should always come on in the top
zone. If the prox fails to cycle in the top zone and Bcam comes on,
this fault will occur. Make sure the cams are set correctly and that
the prox check cycles in the top zone. Refer to Chapter 2 Section xiii
for a graphical illustration. Press the PP150 reset button to reset
the fault.
Message Code 33 & 133 – NO CAM OVERLAP AT BOTTOM
Bcam and Tcam need to be set so that the degree Bcam turns off, and
the degree Tcam turns on overlap. If this does not happen, this fault
will occur. Refer to Chapter 2 Section xiii for a graphical illustration
on default settings for cam switches. Press the PP150 reset button
to reset the fault.
Message Code 34 & 134 – BCAM CYCLED TWICE AT BOTTOM
This fault occurs when Bcam cycles normally, but cycles again after
Tcam turns on and before Tcam turns off. Refer to Chapter 2 Section
xiii for a graphical illustration on default settings for cam switches.
Press the PP150 reset button to reset the fault.
Message Code 35 & 135 – PROX CYCLED AND NO BOTTOM ZONE
This fault occurs when the prox check cycles normally, but Bcam and
Tcam do not overlap. It can also be the case that Bcam never cycled
before Tcam came on. Check to make sure that the cams are working
properly and the windows are set correctly. Press the PP150 reset
button to reset the fault.
Содержание Press Pilot 150
Страница 1: ...Toledo Integrated Systems Toledo Transducers Inc Press Pilot 150 Manual And Installation guide ...
Страница 2: ......
Страница 4: ..._ Doc 16302 Press Pilot 150 Manual Page 2 ...
Страница 18: ..._ Doc 16302 Press Pilot 150 Manual Page 16 4 PRESS PILOT 150 SCREENS The pp150 screens have moved to sheet 100 ...
Страница 54: ..._ Doc 16302 Press Pilot 150 Manual Page 52 ...
Страница 55: ..._ Doc 16302 Press Pilot 150 Manual Page 53 ...
Страница 67: ..._ Input Word 3 Figure 11 4 Doc 16302 Press Pilot 150 Manual Page 65 Input Word 2 Figure 11 3 ...
Страница 68: ..._ Doc 16302 Press Pilot 150 Manual Page 66 Input Word 4 Figure 11 5 Input Word 15 Figure 11 6 ...
Страница 69: ..._ Doc 16302 Press Pilot 150 Manual Page 67 Input Words 4 40 Figure 11 7 ...
Страница 71: ..._ Doc 16302 Press Pilot 150 Manual Page 69 Output Word 1 Figure 11 10 ...
Страница 73: ..._ Doc 16302 Press Pilot 150 Manual Page 71 ...
Страница 83: ..._ Doc 16302 Press Pilot 150 Manual Page 81 Figure 16 5 Figure 16 6 ...
Страница 86: ......
Страница 87: ...MAIN RESOLVER ENCODER CAMS ...
Страница 88: ......
Страница 89: ......
Страница 90: ......
Страница 91: ......
Страница 92: ......
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ......
Страница 99: ......
Страница 100: ......
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ......
Страница 115: ...Doc 16302 Press Pilot 150 Manual Page118 Figure 8 Figure 9 ...