![Tokyo Hy-Power HL-2.5KFX Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/tokyo-hy-power/hl-2-5kfx/hl-2-5kfx_instruction-manual_1125169018.webp)
10. Band Data Cable Connection
This section explains about the methods of the auto band setting Collaboration
with the modern transceivers of ICOM, Yaesu and Kenwood.
To make this setting, it is needed that the band data cable is connected to
“CONT” connector as well as selecting “SELECT” for the proper radio
manufacturer.
Turn off AC powers of both the amplifier and the transceiver when you connect
this data cable. Be sure to confirm the auto band set on each band, after you
finish above settings.
Manual Band set
CONT SELECT
Auto Band set/ CI-V
10-1
ICOM DC Voltage Band Data
①
HL-2.5KFX
Setting
SELECT: “I”
LCD:
“ICOM”
Wiring: Fig.
A
②
Transceiver
Setting
None
Caution:
This method fails to discriminate
24 and 28 MHZ of WARC bands.
ICOM-REGACY BAND DATA
ICM G
ICM
3.5mm PHONE PLUG
TRX ACC
8
15
7
14
6
13
5
12
4
11
3
10
2
9
1
<Fig. A>
17