Q
FIELD STORAGE MODE
R. R
Image
output
3. Typical Examples of RESTART-RESET Operation
Random shutter operation, obtained one fame image, combined with RESTART-RESET and
strobe light.
Q
Setting inside of the camera
CONTROL BOARD
S4-3 ; ON
The strobe light is flashed by R.R (reset point). And the signal stored while strode light flashed
can be obtained at IMAGING A and IMAGING B as the below diagram. Then, the frame image
can be obtained without waiting time.
Q
FRAME STORAGE MODE
RESET point
RESET point
Strobe
light
Image
output
R. R
- 11 -