High-resolution CCD Camera
Model CS3910H
Operation Manual
TOKYO ELECTRONIC INDUSTRY CO., LTD.
2000-09-21
Version 1.2
Страница 1: ...High resolution CCD Camera Model CS3910H Operation Manual TOKYO ELECTRONIC INDUSTRY CO LTD 2000 09 21 Version 1 2...
Страница 2: ...his mark warns the user that improper use indicated with this mark may cause personal injuries 1 or material damages 2 against the user or people around him her Notes 1 Personal injuries mean wounds b...
Страница 3: ...ody discontinue the use immediately In the event that grits small particles or any other foreign objects get inside do NOT try to continue to use the device To do so invites a fire or an electric shoc...
Страница 4: ...e liquids inside the bottle etc may get into the chassis causing a fire or an electric shock accident Avoid Do NOT short circuit signal outputs Avoid short circuit of signal outputs Otherwise it may c...
Страница 5: ...ng the camera with its inner parts circuits in wet condition may cause a damage or an electric shock accident RESTRICTION FOR USE Do not attempt irregular signal interface other than specified Under s...
Страница 6: ...ata read out CCD featuring ultra high resolution 2 FEATURES 1 Ultra high Resolution CS3910H features an ultra high picture resolution through the adoption of a MEGA pixel CCD Total pixel counts 1 400...
Страница 7: ...on 7 Double speed Scan Mode The double speed scanning 24 frame second is available by using mixed reading out scanning method to read each vertical 2 pixel out at the same timing 8 Partial scan Mode T...
Страница 8: ...t 2 DATA OUT Connector Digital Data Output Terminal This terminal is for outputting video signal and HD VD and CLK in RS 644 format For connection with an image processing equipment 6 HOW TO MOUNT YOU...
Страница 9: ...10R 12PB Manufactured by HIROSE DENKI Plug Cable side HR10A 10P 12S Manufactured by HIROSE DENKI 2 DATA OUT Connector Camera side DX10A 36S Connector Cable side DX30A 36P DX 36 CV 1 Cover DATA0 LSB D...
Страница 10: ...ON ON Normal Shutter 1 OFF XXXX OFF ON ON XXXX OFF XXXX OFF RTS Pulse Mode OFF RTS Fix Mode 1 OFF ON Notes 1 Normal E shutter doesn t work under partial scan mode 2 Under RTS Random Trigger Shutter an...
Страница 11: ...RTS Random Trigger Shutter mode when TRIG terminal voltage is in HIGH More than 1V and starts light exposure at the falling edge timing Under FIX mode the exposure time is controlled with inner DIP sw...
Страница 12: ...e the VD ex sync is not The double speed scan doesn t work Video Output Timing 1 Under FIX mode The VD is output in sync with the next HD after light exposure 2 Under PULSE mode The VD is output in sy...
Страница 13: ...is made more than one time before the readout signal input superposed images are output After video output it goes back into the normal operation shutter OFF if the TRIG terminal voltage stays in LOW...
Страница 14: ...re readout individually This allows multiple image processing on a serial basis requiring only one image processor 13 Exposure TRIG Readout E VD CCD exposure VIDEO OUT HD SUB SG Phi VINH WEN TRIG CAME...
Страница 15: ...while the VD ex sync operation is not The double speed scan doesn t work Screen Center 1 2 Readout Total Lines 1034 Lines Scanning Area 474 Lines 14 High speed Transfer Open Area 280 Lines Normal spe...
Страница 16: ...g output 1 0V p p 75 ohm Unbalanced AGC Video signal output fluctuation of plus minus 2dB or less against standard subject illumination minus 6dB Enabled under normal mode only External input signal T...
Страница 17: ...ulse mode Exposure time determined by pulse length Partial scan ON OFF selectable Initial factory setting OFF ON Screen center 1 2 readout Multiple shutter ON OFF selectable Initial factory setting OF...
Страница 18: ...h Y axis Relative response 10 TIMING CHART 10 1 Analog output 1 H rate 1 CLK 49 4ns 20 245MHz H SYNC A 2 47 micro s HBL B 15 61 micro s Front porch C 4 94 micro s Back porch D 8 20 micro s DATA E 64 2...
Страница 19: ...scan mode A 3H A 2H B 14H B 7H C 9H C 4H D 2H D 1H E 1030H E 515H F 1044H 12Hz F 522H 24Hz ENLARGED VIEW V RATE A 1 Under normal mode VD VIDEO H rate a 79 82 micro s V SYNC b 4 94 micro s 2 Under RTS...
Страница 20: ...VDS Driver output voltage Plus minus 350mV Differential output 100 ohm HD DATA CLK Total clock counts 1616CLK 1H DATA counts 1300CLK 1H CLK 49 4ns V rate phase Same as one in analog timing chart HD VD...
Страница 21: ...t timing 1 Under normal E shutter operation 2 Under RTS operation 2 1 Fixed speed mode 2 2 Pulse mode 20 CCD Exposure Video Output WEN TRIG CCD Exposure Video Output HD VD WEN TRIG CCD Exposure Video...
Страница 22: ...11 EXTERNAL VIEW DRAWING 21...