background image

* "MANU" (Manual)

Turning to "MANU" position, take a white object such as

a white paper or white wall all over the screen and

adjust the white balance with the knobs of (R) and (B)

while watching the color monitor. For more information

on color temperature and white balance, refer to the

supplemental informations of pages 13 and 14.

(4)"SHUTTER" (Electronic shutter)

Switches for an electronic shutter.

The camera

incorporates an electronic shutter with a variable speed

function ranging from 1/50 to 1/10,000th seconds, allow

ing of a subject moving at a high speed.

Usually, put "OFF" position at the left side, which is

set a shutter speed of 1/50 sec.

When required

electronic shutter, put it "ON" position and select any

of "F.L"/ "AUTO"/"MANU" on the camera control unit.

* "F.L" (Flickerless)

Where the illumination of fluorescent lamps are used in

the power frequency area of 60 Hz, a flicker may appear

on the picture. And if turned to "F.L" position, it will

be set the shutter speed 1/120 sec., resulting in

decrease the flicker on the picture.

* "AUTO" (Automatic Sensitivity Control)

This camera is provided with an automatic sensitivity

control which adjusts the shutter speed according to the

amount of light entering the lens so that correct

exposure is obtained even when illumination of the

object changes. Fixed shutter and manual control are

also possible.

* "MANU" (Manual)

When a subject moving at high speed is shot by the

camera, put it "MANU" position. And select any one of

shutter speeds of 1/50, 1/125, 1/250, 1/500, 1/1000,

1/2,000, 1/4,000, 1/10,000 sec. as necessary.

-

6

-

Содержание CS6100P

Страница 1: ...For customer Use Enter below the Serial No which is located on the rear panel of the camera control unit Retain this information for future reference Model No _CS6 100P Serial No __________ TOKYO ELE...

Страница 2: ...led and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception If does so which can be determined by turning the equip...

Страница 3: ...N 13 1 Color temperature 13 2 White balance 13 3 How to get good color 13 4 Color temperature of various 14 artificial lighting 5 CCD image sensor 14 6 Smear 15 7 ASC and AGC 15 8 Lenses 15 6 TROUBLE...

Страница 4: ...ra lens directly into sunlight or strong artificial light This might cause irreparable damage to the image sensor Also be sure to use the lens cap when the camera is not in use 5 Do not expose the cam...

Страница 5: ...ack Do not use longer screws inserted over 3 5mm from the bottom chassis when the camera control unit is installed to anything board Because there is a printed circuit board closed to the bottom chass...

Страница 6: ...otate the iris ring toward CLOSE clockwise To increase aperture rotate the iris ring toward OPEN counter clockwise Adjust the lens aperture according to the amount of light entering the lens so that c...

Страница 7: ...trically in low light situations Set AGC switch to ON when illuminationis not sufficient on the subject Normally put it OFF position 3 WHITE BALANCE The picture taken with a camera is sometimes advers...

Страница 8: ...e under a fluorescent light or when shooting and closing up a subject with large colored area this control system cannot work properly and also cannot obtain good color imetry color reproduction The p...

Страница 9: ...r put it ON position and select any of F L AUTO MANU on the camera control unit F L Flickerless Where the illumination of fluorescent lamps are used in the power frequency area of 60 Hz a flicker may...

Страница 10: ...ents are located at the side panel on the camera control unit GAMMA SYNC H SC 1 SC Sub carrier phase When synchronized by an external VBS the color phase SC must be adjusted After making rough adjustm...

Страница 11: ...for non linear characteristics of image signals based on CRT s electron gun in TV receiver and the total performances of the video system have linear gamma 1 Usually use the gamma correction ON positi...

Страница 12: ...o connect between equipments 4 1 Typical connection Camera head cover Lens for CS6100P Camera head Camera head mounting kit VBS OUT Y C OUT RGB HD VD SYNC OUT Camera control unit rear panel DC input c...

Страница 13: ...for B on the RGB OUT connector They can be connected the use of the monitor provided R G and B individual input terminals 2 Pulse outputs Use them when other equipments required pulses HD VD SYNC to...

Страница 14: ...allows reduction of cross color dot disturbance and color blurring that may occur especially during picture editing compared to the PAL composite video signal Use the equipments with S terminal in the...

Страница 15: ...ernal sync operation And input VBS or SYNC from pin 9 and 8 GND for external sync operation by VBS or SYNC When used HD VD or SYNC the system should be synchronized for HD and VD phase When VBS the sy...

Страница 16: ...ensate for color temperature variations of light so that whites are reproduced as white Correct white balance makes all other colors correct The CS6100P can perform automatic white balance adjust ment...

Страница 17: ...onductor technology Minute pixels of 400 000 active pixel consists of 752 X 582 or so are integrated in ultra high density on the small area of 4 8mm H X 3 6mm V by utilizing sophiscated semi conducto...

Страница 18: ...still camera Meanwhile just like in a 35mm camera the program AE mechanism housed in the video camera automatically selects the speed of the electronic shutter depending on the lighting Simultaneousl...

Страница 19: ...colors Have you moved to a greatly differ different location after from actual adjusting white balance subject colors Or have you shot after 5 hours have elapsed from the last white balance adjustmen...

Страница 20: ...s 2 1 interlace Internal External automatic change over 15 625 kHz 50 Hz 4 3 2500 lux at F8 3000K 10 lux F1 4 AGC ON output level for 25 9 Video output PAL VBS 1 0 Vpp 75 Y C S terminal 1 0 Vpp 75 RGB...

Страница 21: ...d Camera control 15 625 kHz 50ppm 50 Hz 50ppm 1 0 Vpp 75 positive polarity 15 625 kHz 50ppm 50 Hz 50ppm 4 433619 MHz 50ppm TTL level negative polarity negative polarity negative polarity 0 45 1 select...

Страница 22: ...kit 1pc DC input connector CPCN3440 1pc Operation manual 1pc 4 Optional Accessories Purchase the following optional accessories depending on your system as necessary Lens Focal length Extension camer...

Страница 23: ...9 APPEARANCES 1 Camera head 20 2 Camera mounting kit...

Страница 24: ...3 Camera control unit 21...

Страница 25: ...afety checks have been performed to determine that the video product is in safe operating condition Unauthorized parts may result in fire electrical shock or other hazards 5 When you send the product...

Страница 26: ...5 82 3226 Tokyo Office 1 18 Iwamoto cho 2 chome Chiyoda ku Tokyo 101 Japan Phone 03 3863 6631 Fax 03 3863 6650 Telex 272 3287 Kansai Office 1 2 Sakaemachi dori 2 chome Chuo ku Kobe city 650 Japan Phon...

Отзывы: