Features 

0 Multi input signal and multi models for option. 

0 With measured display, control output, alarm output, analog output, RS485 

communication, etc. 

0 Multi PID algorithms for option, with auto tune function. 

0This product can be used in industrial machinery, machina tools, general measuring 

instruments and equipment. 

National High-tech Enterprise/ National Standard Drafting Unit 

Hotline : 400-0760-168 

Version code : KKTP-C01E-A/1-20201026 

The instruction explain instrument settings, connections,name and etc, 

please read carefully befare you use the temperature controller. Please keep it 

properly fer necessary reference. 

l. Safe Caution

..t.Warning 

1 ) When the failure or abnormal of products lead to a system of major accidents, 

please set the proper protection circuit in the extemal. 

2 )  Please don't plug in before completing all the wire.Otherwise it may lead to electric 

shock, fire, fault. 

3 ) Not allow to use outside the scope of product specification,otherwise it may  lead to 

fire,fault. 

4 )  Not allow to use in the place where is inflammable and explosiva gas. 

5 )  Do not  touch power terminal and  other high voltage part when the  power on 

otherwise you may get an electric-shock. 

6 ) Do not remove,repair and  modify  this  product,otherwise it may  lead  to electric 

shock, fire, fault. 

..t.Caution 

1 )  The product should not be used in a nuclear facility and human life associated 

medical equipment. 

2 )  The product may  occur radio interference when it used at home.You should take 

adequate countermeasures. 

3 )  The product get an electric shock protection through reinforced lnsulation. When the 

product is embedded in the devices and wiring,please subject to the specification of 

embedded devices. 

4 ) In order to prevent surge occurs,when using this product in the place of over 30m 

indoor wiring and wiring in outdoor,  you need to set the proper surge suppression 

circuitry. 

5 )  The product is produced based on mounting on the disk.In order to avoid to touch 

the wire connectors,please take the necessary measures on the product. 

6 )  Be sure to observe  the precautions in this  manual,  otherwise there is a risk of a 

major injury or accident. 

7 ) When wiring, please observe the local regulation. 

8 )  To prevent to damage the  machine  and prevent to machine failure, the product 

is connected with power lines or large capacity input and output lines and other 

methods please install proper capacity fuse or other methods of protection circuit. 

9 )  Please don't put metal and wire clastic mixed with this product,otherwise it may lead 

to electric shock, fire, fault. 

10 )  Please tighten screw torque according to the rules.lf  not,it may  lead to electric 

shock and fire. 

11 ) In order not to  interfere with this products to dissipate  heat,  please don't plug 

casing around the cooling vent hole and equipment. 

12)  Please don' t connect any unused terminal. 

13)  Please do the cleaning after power off, and use the dry cleaning cloth to wipe away 

the dirt.  Please don' t use desiccant, otherwise, it may  casue the deformation or 

discoloration of the product. 

14 )  Please don't knock or rub the panel with rigid thing. 

15 )  The readers of this manual  should  have  basic  knowledge of electrical, control, 

computer and communications. 

16 )  The  illustration, example of data and  screen in this manual is convenient to 

understand,instead of guaranteeing the result of the operation. 

17 ) In order to use this  product with  safety  for  long-term,regular maintenance is 

necessary. The life of sorne parts of the equipments are by sorne restrictions, but the 

performance of sorne will change for using many years. 

18 ) Without prior notice, the contents of this manual will be change. We hope these is 

no any loopholes, if you have questions or objections, please contact us. 

Caution of lnstall & Connection 

1. lnstallation 

1)  This  product  is  u sed  in  the  following  environmental  standards.

( IEC61010-1 )  [Overvoltage categorylI,  class of pollution 2] 

2)This product is used in the following scope:environment, temperatura, humidity and 

environmental conditions.Temperature:0-50

º

C;humidity: 45-85%RH; Environment 

condition:lndoor warranty.The altitude is less than 2000m. 

3) P l e a s e   a v o i d   u s i n g   in  t h e   f o l l o w i n g   p l a c e s : 

The place will be dew fer changing temperature;with corrosiva gases and flammable 

gas; with vibration and impact;with water, oil, chemicals, smoke and steam facilities 

with  dust, salt, metal powder;and with  clutter interference, static electric and 

magnetic fields, noise;where has air conditioning or heating of air blowing directly to 

the site; where will be illuminated directly by sunlight; where accumulation of heat will 

happen causad by radiation. 

4) On the occasion of the installation, please consider the following before installation. 

In order to protect heat saturated, please ensure adequate ventilation space. Please 

consider connections and environment,and ensure that the products below for more 

than  50mm space. Please avoid to installed over the machina of the calorific  value 

(Such as heaters, transformar, semiconductor operations, the bulk resistance). When 

the surrounding is more than 50 , please using the force fan or cooling fans. But don't 

let cold air blowing directly to the product. In order to improve the anti - interference 

performance and  security,  please try  to stay  away  from high  pressure  machines, 

power machines to install. Don't install on the same plate with high pressure machine 

and the product. The distance should be more than 200mm between the product and 

power line. 

2. Cable caution  : 

1 )  Please use specified compensation wire  in the  place  of TC input;  Please use 

insulated TC if the measured device is heated metal. 

2 )  Please use the cable of lesser resistance in the place of RTD input,and the cable (3 

wire) must be no resistance difference,but the total length is within 5m. 

3 )  In order to avoid the effect of noise,please put the input dignal away from meter 

cable,power cable.load cable to wiring. 

4 )  In order to reduce the power cables and the load power cables on the effect of this 

product,  please use noise filter in the place where easy  to effect. You must install 

it on the grounding of the disk if you use the noise filter,and make the wiring to be 

shortest between noise filter output side and power connectors. Don't install fuse 

and switch on the wiring of noice filter output side,otherwise it will reduce the effect of 

noise filter. 

5 )  lt takes 5s from input power to output.lf there  is a place  with interlocking actions 

circuit signal,please use timer relay. 

6 )  Please use twisted  pair with a  shield for analog output line, can also connect  the 

common-mode coil to the front-end  of the signal receiving device to suppress  line 

interference if necessary, to ensure the reliabilty of signal. 

7)Please use twisted pair with a shield for remete  RS485 communication cable,  and 

deal with the shield on the host side earth, to ensure the reliabilty of signal. 

8 )  This product don' t have the fuse; please set according to rated voltage 250V, rated 

current 1A if you need; fuse type:relay  fuse. 

9)  Please use  suitable slotted screwdriver and wire. Terminal distance:  5.0mm. 

Screwdriver size: 0.6X3.5, length of slotted screwdriver >130mm. Recommended 

tightening torque: 0.5N.m. Proper cables: 0.25  - 1.65mm single cable/multiple core 

cable 

10 )  Please  don't  put the  Crimp  terminal or bare  wire  part  contact with  adjacent 

connector. 

11.  Model lllustration 

TP4D-D R C 1 8 D-

e-

O  C:  Version 

D  Blank: TC/RTD/mV/Rt input  X: mA/V input 

D  1 O:  Single input without RS485 

18: Single input with RS485 

D  B: One alarm  C: Two alarms  A: No alarm 

D  R: Relay output  S:SSR output  D:DC 4-20mA(lt 

can be changed to analog output by ACT menu) 

K: SCR output (to be ordered) 

M:SSR/Relay (switched by ACT) 

,...__ _____ 

Blank:No  l:DC 4-20mA analog output (it can be 

changed to control output by ACT menu, available 

fer size 6, 9) 

�------ O  Blank:AC/DC 100-240V 

F:AC/DC 24V(to be ordered) 

,___ _______ D  4 : 48H*48W*71 L  7 :  72H*72W*71 L 

6  :  96H*48W*71 L  9 :  96H*96W*71 L 

,...__ ________ D  TP Series temperature controller 

111. Models

OUT1 control output  Alarm output  Analog  Comm. 

Auxillial) 

No. 

Model 

output 

power 

RELAY SSR 4-20mA  ALl  AL2 4-20mA RS485  24V 

OUT2 

TP4-DC18D 

• 

@) 

•  • 

TP4-DC10D 

• 

@) 

• 

TP4-RC18D 

• 

• 

TP4-SC18D 

• 

• 

TP4-MC10D 

• 

• 

TP7-DC18D 

• 

@) 

•  • 

TP7-DC10D 

• 

@) 

• 

TP7-MC18D 

• 

• 

• 

TP7-MC10D 

• 

• 

10 

TP6/9-IMC18D 

•  •  • 

@) 

•  • 

11 

TP6/9-IMC1 OD 

•  •  • 

@) 

• 

12 

TP6/9-DC18D 

• 

• 

@) 

•  • 

13 

TP6/9-DC10D 

• 

• 

@) 

• 

14 

TP6/9-MC180 

•  • 

• 

15 

TP6/9-MC10D 

•  • 

• 

o : Blank: input signal is TC/RTD/Mv/Rt; "X" : input signal is 4  -

20mNO 

- 1 OV 

• : Standard configuration function 

@ : The meter has this function, but it is combined with another function. This 

series only have ene loop 4-20mA output, but the user can modify menu ACT to 

set it as main control output or analog  output. 

IV. Specifications

1. Electrical parameters: 

Sampling rate 

2 times per second 

Relay capacity 

AC 250V /3A Life of rated load>100,000 times 

Power supply 

AC/DC 100  - 240V (  85-265V ) 

Power consumption  < 6VA 
Environment 

lndoor use only, temperature: 0-50

º

( no condensation, 

humidity < 85%RH, altitude<2000m 

Storage 

-10  - 60

º

C, no condensation 

enenvironment 

www.toky.com.cn / www.csrimport.com