V. Operations

The second row LED is defaulted to display range and input channel alternately after power on, press (   ) to display range only, press (   ) to returns 

to  default display

In the measuring status, press SET >3S to enter setting menu. 

When modifying setting value, press    /    to change value; press (   ) key to shift decimal point; after modifying, press SET key to confirm and enter

     next menu. After setting, press SET key more than 3S to exit menu; if there is no operation for a long time, it will exit menu automatically.

 △

II. Technical Specification

Power Supply
Display range
Accuracy
Analog output

Relay capacity

Dielectric Strength

AC/DC  100

240V  50Hz/60Hz  DC 24V(Need to be ordered)

0.001-9999 float decimal point display
±0.5%F.S ±2digits(For AC signal frequency under 100Hz

4

20mA load capacity

600

Ω

, accuracy:±0.5%F.S 

AC 250V/3A or DC 30V/5A
Between power supply connector and other connectors, relay output connectors and other connectors, AC 1800V leakage 
current 0.5mA,60S;Between input signal connectors and low voltage signal output connectors, DC 600V leakage current 
0.5mA,60S

96W*48H*100L

Communication

Insulation Impedance
Working environment

Sampling rate

Temperature

0-50

       Humidity

85%RH

5 times/S

Dimension

RS485 communication interface,Modbus RTU Protocol

100M

Ω

/500V DC

III. Panel Illustration

Decrease key

Increase key

Shift key

AL1:Indicating lamp for alarm 11#
AL2:Indicating lamp for alarm 12#

SET: Parameter select/confirm key

Displaying setting value

or parameter setting

Displaying measuring value/parameter code

A(mA): Current indication lamp

V: Voltage indication lamp

Psge 02

 No.

1

2
3

5
6

Paremeter code Setting range

Factory value

Indication

INP

Ad1

AL1

Ad2

AL2

rH

rL

Add
bAd

LCK

4

7
8
9

Ct

PS

10
11
12
13
14

Hy1

Hy2

IN1

IN3

For range A1000, the default one is IN1

for range A1

the default one is IN2

for range V600

the default one is IN3

H
90% of measuring range

10% of measuring range

maximum of the range
minimum of the range
001
9.6
000

1.000

1.000
1.000
0.000

L

H or L

H or L

-1999

9999

-1999

9999

-1999

9999

-1999

9999

-1999

9999

-1999

9999

-1999

9999

0

9999

0

255

0

255

4.8 or 9.6

AL,HY,Ct,PS,rH,rL 

have the sameunit as 

the Range.

IV. Connection drawing

Note:please subject to the diagram on the product if any changes.

Voltage input

20

19

18

17

16

15

14

13

12

11

   AC/DC

100

240V

   AC/DC

100

240V

IN2 IN1

IN3

10

9

8

7

6

5

4

3

2

1

-

+

4

20mA

AL2

AL1

B- A+ COM

GND

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

-

+

4

20mA

AL2

AL1

B- A+ COM

COM2 COM1

Current input