Maintain good balance on both feet. Keep proper distance from the chisel of the Rock Drill.   
Never put your hand near the rod when using the Rock Drill horizontally.   
Push the Rock Drill against the object firmly using the handle before turning the throttle valve level.   
Obey the law and safety regulations.   
 

CAUTION:Pressing the Rock Drill with proper force 

Pressing  the  Rock  Drill  on  the  object  too  strong,  much  load  is  applied  to 
rotation parts and these parts wear out quickly. 
It  depends  on  the  rock  quality  but  basically  the  maximum  pressing  force  at 
vertical drilling is 55kgf. 
If  the  Rock  Drill  is  used  for  a  long  time  with  higher  pressing  force  than 
maximum value, it might lead to the quick wear or premature failure for internal 
parts. 
Conversely, if pressing force is too weak, the Rock Drill works intensely and 
cause high vibration. 
Then  it  might lead  to  high burden  and early  fatigue  for  workers,  and  lead  to 
quick wear for the consumable parts. 
 
Inspection and maintenance 

WARNING 

Turn valve cock of the compressor to the stop position first, turn the throttle valve level of the Rock Drill and 
release the excess pressure in the air hose completely, then disconnect the Rock Drill from the air hose and 
finally inspect the Rock Drill.

 

   
Inspection and storage for a Rock Drill 
Clean the exterior surface using a cloth.   
Regularly inspect the tightening torque on the bolts.   
Inspect whether there are any cracks or damage in the Rock Drill.   
 
Storage of the Rock Drill 
Apply 3 cc of oil from the air inlet. operate the Rock Drill for about 5 seconds after completing work.   
Repeat above operation 2-3 times before storing the Rock Drill.   
Put a cap on the air inlet of the Rock Drill to prevent any dust or foreign material from entering the   
Rock Drill. Keep the Rock Drill in a dry place.   
 
Loss of power/erratic action (possible causes)

 

1.    Reduced compressor output. 
2.    Excessive drain on air line. 
3.    Moisture or restricted pipe, hose or fittings. 
4.    Improper size or poor condition of pipe, hose or fittings. 
5.    Incorrect shank size of chisel, or excessively worn shank. 
6.    Free running (or blank blow) can cause damage to the tool. Always hold the tool down to the work. 
7.    Loosening of side bolts or back head bolts will cause loss of power and can cause damage to the tool. 

Periodic inspection of bolt torque at regular intervals (at least once a week if tool is being used regularly) 
is recommended. 

If  everything  else  appears  to  be  in  order,  then  disassemble  tool,  replace  worn  or  damaged  parts,  clean, 
reassemble and lubricate. 
 
Replacement parts 
Always use GENUINE TOKU TOOL Replacement Parts. 
When replacement parts are required, order by Part Number and Description from the Parts List. 
 
 

 

 

 

Содержание TS-55

Страница 1: ...OT DISCARD GIVE TO USER Do not use a Rack Drill until this safety instruction has been read and understood completely This manual is necessary to help you to use the Rock Drill correctly WARNING Do no...

Страница 2: ...any modifications concerning the air tool The manufacturer will not assume any responsibility concerning an accident resulting in injury death or any trouble from an air tool due to the reconstructio...

Страница 3: ...and telephone cable water and drain pipe etc inspect for hidden cable or pipe underground before operating an air tool In case the chisel hits something during operation stop the air tool immediately...

Страница 4: ...ction gloves and working shoes are worn correctly Air Supply Whether the air pressure is suitable For best operation supply tool with 90psig 6 2bar of clean dry air Higher pressure drastically reduces...

Страница 5: ...the Rock Drill Inspection and storage for a Rock Drill Clean the exterior surface using a cloth Regularly inspect the tightening torque on the bolts Inspect whether there are any cracks or damage in...

Страница 6: ...ISO 15744 Sound pressure level LpA 108 43 dB A Uncertainty KpA KWA Sound power level LWA 119 43 dB A 3 dB Vibration value ISO 28927 10 Declared vibration emission value ahd Uncertainty K 25 m s2 3 0 m...

Страница 7: ...MEMO 7...

Страница 8: ...aru Miyaki machi Miyaki Gun Saga Japan 4 declare that the product s ROCK DRILL 5 Model Type S 55 6 Version s S 55 TS 55 PK 280 L 7 Starting Serial No 11J001 8 is in conformity with the requirement of...

Страница 9: ...ble s 11 NOM et FONCTION de l metteur 12 Place et data ITALIANO ITALIAN 1 DICHIARAZIONE DI CONFORMIT CE 2 La Societ TOKU 3 File tecnico disponibile dal 4 dichiara che il i prodotto i Perforatore 5 tip...

Страница 10: ...TS 55 Parts List Exploded View 6th edition 10...

Страница 11: ...7C 13 11 01 023 O RING P 24 1 30 43 03 06 W70 FRONT HEAD L 1 8 43 03 01 B30 AIR CONNECTION NUT 1 43 03 01 W60 FRONT HEAD S 1 9 43 03 01 B50 AIR CONNECTION WASHER 1 31A 43 03 06 H60 ROTATION SLEEVE L 1...

Страница 12: ...12 MEMO...

Отзывы: