background image

CONFIGURATION MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAGLINK LX 

 

 

 

 

 

 

 

 

 

 

 

Rev. 09 – April 2016

Содержание ProGauge MAGLINK LX

Страница 1: ...CONFIGURATION MANUAL MAGLINK LX Rev 09 April 2016...

Страница 2: ...This page is left intentionally blank...

Страница 3: ...TORY 11 7 2 ALARMS 11 7 3 DELIVERY LOSSES 12 7 4 CURRENT STATUS 13 7 5 SENSOR STATUS 13 8 THE ADMIN PAGE 14 8 1 SYSTEM 14 8 2 TANK 16 8 3 STRAPPING TABLE 17 8 4 RELAYS 18 8 5 SENSORS 18 8 6 RECONCILIA...

Страница 4: ...rights reserved 2 GENERAL WARNINGS Before working on this equipment please carefully read this instruction in this manual Authorised and trained personnel must perform configuration changes and updat...

Страница 5: ...onsiderations IMPORTANT Danger to persons including death to property or to the environment The following table lists reference data of the manufacturer Data Description Name START ITALIANA S r l Addr...

Страница 6: ...th each MagLink LX The web application is designed to configure and set parameters in the console In addition you can also display a variety of information The status of all connected tanks The data o...

Страница 7: ...ry Losses X X Login X X Logout X X Association of alarm to relays per tank X Managing internal and external sensors X Automatic print features X Definition and insertion of strapping table per tank X...

Страница 8: ...of login access Login access Password Guest GUEST LX Admin MAGLINK LX You can only change the password by logging in as Admin ATTENTION The administrator must change the password as soon as possible t...

Страница 9: ...me page Name of the current page Type of access Guest or Admin Current date or time Web versions console and serial number From any page you can go to home page to change language for web application...

Страница 10: ...in menu 3 It opens the Login page with the ability to change your password 4 Press the Change password button 5 Type the current password and the new password then press the Confirm button 6 The appli...

Страница 11: ...aved data at regular intervals in a log file for future analysis You can select from the following filters Year Month Day Tank Pressing the button Display tank tank displays the data with the consider...

Страница 12: ...For alarms in progress 7 3 Delivery Losses The following image shows the Delivery Losses Page The page shows the Delivery data White background colour lines and related losses Red background colour li...

Страница 13: ...All tanks Data of all tanks is displayed one after the other 1 32 The selected tank data is displayed The page is reloaded automatically every minute and shows the latest information You can refresh t...

Страница 14: ...ia TCP Temperature of comp volume Selectable values for the calculation of the compensated volume 15 C 20 C Station name Station name History range Time interval between a history saving data ATTENTIO...

Страница 15: ...owing table shows the configuration of the dipswitches Dipswitch Description 1 OFF Single Gilbarco ON Double Gilbarco 2 3 5 8 Not used 4 OFF Relay in normal mode ON Relay in reverse mode 6 Resetting p...

Страница 16: ...of the product read only value Offset Value used to calibrate the position of the product float Possible values 30 000 mm Zero water Value used to calibrate the water float Resolution 1 mm Maximum va...

Страница 17: ...on lines to be deleted after finishing ticking all the lines press the Delete button 2 Import Table When you have a Strapping table in Excel CSV format you can import it by using the Choose File and...

Страница 18: ...range Very low High Probe Communication ATTENTION When using the DVD do not use Relay 4 as its used to power the DVD 8 5 Sensors In this section user can configure internal and external sensors User m...

Страница 19: ...MAGLINK LX Configuration Manual Admin Pages Rev 09 April 2016 Page 19 of 28 The following image shows the Sensors page Probe type External Card Start Italiana S r l...

Страница 20: ...conciliation the console receives information on the amount of fuel dispensed The user can compare the dispensed volume Dispenser column by the hour with the difference in volume per hour detected by...

Страница 21: ...tion The following image shows the Config Page Dispensers When the console is connected to an FCC or POS enabled for reconciliation configure the dispensers and its nozzle s associating them to the ta...

Страница 22: ...enters in Delivery mode an e mail to the address list is sent ATTENTION Carefully configure the SMTP settings in SMTP Configuration then press the Save SMTP button In the Address List section you can...

Страница 23: ...of the GSM modem Basic operations 1 Disable the PIN code from the SIM card before insert it into the modem 2 Insert the SIM card into the dedicated slot of the modem 3 Power on the console and wait so...

Страница 24: ...o reboot the operating system Shutdown application Press Shutdown application to close application Reset to factory default Press the Reset button Configuration Backup Restore Backup function once the...

Страница 25: ...must be connected to the computer to which Start Italiana S r l will connect remotely In the case no Internet access is available the user can provide Start Italiana S r l with console data to debug o...

Страница 26: ...ation Section and a Notification Section 2 1 x 05 April 2015 New test reports certification and notification 2 1 x 06 July 2015 Manual updated procedure information reconciliation shift reports stock...

Страница 27: ......

Страница 28: ...START ITALIANA S r l Via Pola 6 20813 Bovisio Masciago MB Italia Tel 39 0362 1581465 Fax 39 0362 1581464 support startitaliana it www startitaliana it...

Отзывы: