background image

 

-  23  - 

 
 

5.5 

Common  parameter  setting  mode  SET  4  (2) 

 

SET04

 

Name 

Setting content 

Initial value 

31 

MV2 

Secondary control operating amount 

0.0 to 100.0 (%) 

0.0 

32 

PC1 

Secondary control proportional band setting for PID 
No. 1 (low temperature) 

0.10 to 10.00 (times) 

1.00 

33 

PC2 

Secondary control proportional band setting for PID 
No. 2 (intermediate temperature) 

0.10 to 10.00 (times) 

1.00 

34 

PC3 

Secondary control proportional band setting for PID 
No. 3 (high temperature) 

0.10 to 10.00 (times) 

1.00 

35 

T2 

Secondary control proportional cycle 

0.1 to 120.0 (seconds) 

1.0 

36 

PS2 

Secondary control loop abnormality 
PV variation setting 

Thermocouple/RTD input 0.0 to 999.9 (

°

C) or 0 to 999 (

°

C) 

0

 

Current/voltage input 0 to 9999 (digit) 

37 

LOP2 

Secondary control loop abnormality time setting 

0 to 3600 (seconds) 

38 

C2 

Secondary control sensitivity setting 

Thermocouple/RTD input 0.0 to 999.9 (

°

C)    0 to 999 (

°

C) 

Current/voltage input 0 to 9999 (digit) 

10 

39 

CP2 

Secondary control off-point position 

Thermocouple/RTD input -999.9 to 999.9 (

°

C) -999 to 999 

(

°

C) 

Current/voltage input -9999 to 9999 (digit) 

40 

PBB 

Manual reset 

0.0 to 100.0 (%) when 

CNT

 = 1 

-100.0 to 100.0 (%) when 

CNT

 = 3 and 4 

0.0 

41 

DB 

Dead band 

Thermocouple/RTD input -999.9 to 999.9 (

°

C) -999 to 999 

(

°

C) 

Current/voltage input -9999 to 9999 (digit) 

42 

O1F 

Target connection output 1 selection 

Connection content selection 

 

0  MV1 

1  MV2 

2  Transmission  output 

43 

TRN1 

Transmission output function setting 

Transmission content selection 

03 

*1  PV (measurement value) output 

*2  SV (setting value) output 

*3  MV 1 (Primary Control Amt.) output 

*4  MV 2 (Secondary Control Amt.) output 

Forward/reverse operation selection 

0*  Forward operation 

1*  Reverse operation 

44 

TRH1 

Transmission scaling upper limit setting 

TRL1

~2999.9(

) or 

TRL1

~2999(

1200 

45 

TRL1 

Transmission scaling lower limit setting 

-1999.9

TRH1

 (

) or -1999

TRH1

 (

46 

O2F 

Target connection output 1 selection 

Connection content selection 

 

0  MV1 

1  MV2 

2  Transmission  output 

47 

TRN2 

Transmission output function setting 

Transmission content selection 

04 

*1  PV (measurement value) output   

*2  SV (setting value) output   

*3  MV1 (Primary Control Amt.) output 

*4  MV2 (Secondary Control Amt.) output 

Forward/reverse operation selection 

0*  Forward operation 

1*  Reverse operation 

48 

TRH2 

Transmission scaling upper limit setting 

TRL2

~2999.9(

) or 

TRL2

~2999(

1200 

49 

TRL2 

Transmission scaling lower limit setting 

-1999.9

TRH2

 (

) or -1999

TRH2

 (

 

Содержание TTM-339

Страница 1: ...a better understanding of them Ensure to store this manual and use it whenever needed Contents Precautions on the use of the products Parts indication and Installation Terminal connection diagram Ter...

Страница 2: ...y due to high temperature under specific conditions Hazard of burst under particular conditions Warning Improper wiring to the equipment may cause a failure such as fire Upon completion of wiring ensu...

Страница 3: ...revised without prior notice Precaution regarding Export Trade Control Ordinance Investigation on client or application by an appropriate party is required so that the equipment is not used for mass d...

Страница 4: ...on In a run Displays the step No etc presently in progress Operating status lower row center 6 segments Indicates the program operating status 2 3 Key No Name Content A RUN STOP key Used for run start...

Страница 5: ...of Event 2 EV3 Lights up at occurrence of Event 3 EV4 Lights up at occurrence of Event 4 TS1 Lights up at Time Signal 1 ON TS2 Lights up at Time Signal 2 ON TS3 Lights up at Time Signal 3 ON TS4 Light...

Страница 6: ...rise to 50 C or higher In case that the temperature of 50 C or higher is suspected use a fan or air conditioner to cool the ambience Take care that no cold air flows directly on the equipment 2 Do not...

Страница 7: ...to output lines secondary side of the noise filter and power terminals for the temperature controller Isolate the noise filter input line primary side from its output line secondary side High frequen...

Страница 8: ...it is stopped with key operation max 9999 times During a run the TIME output is ON For display during the program run see Section 5 3 2 Auto run normal mode The following is displayed upon termination...

Страница 9: ...t each of low intermediate and high temperatures Auto tuning starts when the temperature at which the auto tuning is to be performed is set on each startup screen and the RUN STOP key is pressed or by...

Страница 10: ...use purpose of one relay output is selected from either in a run signal output or end signal output 4 10 1 When selecting the in a run signal output During a run the relay output is always ON as in a...

Страница 11: ...n Operation amount In the case of in a stop Starts with the operation amount of 0 0 In the case of in a run Starts with the operation amount at the time of switchover Step time In the case of in a sto...

Страница 12: ...t changes each time when measuring the current value The final operation amount is limited by using either smaller limit of the above two The function is effective when OUT 2 selection 4 to 20mA CT ex...

Страница 13: ...unt resulted from the calculation the operation amount is eventually limited at 36 0 4 14 3 Other operation amounts limiter setting 4 14 3 1 Primary secondary control operation amount change limiter i...

Страница 14: ...ing is changed control results change redo theAT Operation is performed only at the control start RDY to RUN or MAN orAT Care must be used as no limit applies by the operation amount increase time aft...

Страница 15: ...be delayed for an abrupt change of input Input signal 0 100 100 0 100 0 Damping time constant PdF1 63 Read in input No filter Read in input With a filter 4 16 2 B thermocouple PR40 20 special PV filt...

Страница 16: ...amount setting is 0 4 19 Blind Function RUN OUT EV1 EV2 EV3 EV4 TS1 TS2 TS3 TS4 AUTO MANU AT END TIME PTN STP RUN OUT EV1 EV2 EV3 EV4 TS1 TS2 TS3 TS4 AUTO MANU AT END TIME PTN STP RUN OUT EV1 EV2 EV3...

Страница 17: ...SV SLL Restored at the location at the time of the outage 2 In the case of in a ramp of SV increase or in a soak Restored with the PV start Restored with the run end END if no SV present 3 In the cas...

Страница 18: ...ey 3 seconds 5 6 Common parameter setting mode 5 7 Alarm temperature setting mode 5 8 PID setting mode Reset MODE key Reset MODE key 3 seconds Reset MODE key key 3 seconds Reset MODE key key 3 seconds...

Страница 19: ...MODE key Step 1 operation amount limiter function setting MODE key MODE key MODE key key MODE key key MODE key key MODE key key MODE key Step 1 time signal 1 function existence nonexistence setting MO...

Страница 20: ...Event 1 lower limit setting MODE key key 3 seconds Event 2 upper limit setting Event 2 lower limit setting Event 3 upper limit setting Event 3 lower limit setting Event 4 upper limit setting Event 4...

Страница 21: ...setting mode SET 2 SET02 Name Setting content Initial value Below 1 and 2 are for the wait function setting i e effective when 1 is selected 1 WZ1 Wait zone 1 setting Thermocouple RTD input 0 0 to 99...

Страница 22: ...the PV digit duringAT The SV range is PM2 to SLH 10 12 ATALL AT startup screen for PID No 1 3 Use the RUN STOPkey for start and stop During the auto tuning Character PV is alternately displayed at PV...

Страница 23: ...eset 0 0 to 100 0 when CNT 1 100 0 to 100 0 when CNT 3 and 4 0 0 41 DB Dead band Thermocouple RTD input 999 9 to 999 9 C 999 to 999 C 0 Current voltage input 9999 to 9999 digit 42 O1F Target connectio...

Страница 24: ...er upper limit 1 MLL11 to 100 0 100 0 3 MLL11 Primary control operation amount limiter lower limit 1 0 0 to MLH11 0 0 Below 4 and 5 are for the operation amount limiter function setting i e effective...

Страница 25: ...ion amount limiter point 11 30 AH01 Current value limiter point 1 Upper current limit at the operation amount limiter point 0 0 to 30 0 A 30 0 31 AH02 Current value limiter point 2 32 AH03 Current val...

Страница 26: ...Thermocouple RTD input 999 9 to 999 9 C 999 to 999 C 0 Current voltage input 9999 to 9999 digit 6 PDF1 PV filter setting 0 0 to 99 9 seconds 0 0 7 PDFS Special PV filter setting 0 0 to 99 9 seconds 0...

Страница 27: ...ing 3 LOC 3 Alarm temperature setting mode lock setting 0 Lock turned off 4 LOC 4 PID setting mode lock setting 1 Lock turned on 5 LOC01 Common parameter setting mode SET01 lock setting 6 LOC02 Common...

Страница 28: ...d setting for PID No 3 high temperature 10 I3 Integral time setting for PID No 3 high temperature 11 D3 Derivative time setting for PID No 3 high temperature 5 14 Caution Care must be used for the nam...

Страница 29: ...e voltage range 85 110 Power consumption TTM 339 10VA AC264V Momentary power cut off Within 1 cycle 20mS Cut 100 power off on 100V AC at max power consumption Isolation resistance Measurement terminal...

Страница 30: ...t Control type Select from ON OFF control PID control Power ON Relay contact output SSR drive voltage output Approx 4 sec output 0 4 20mA DC output Approx 4 sec 1mA output PV abnormal Relay contact ou...

Страница 31: ...rature input circuit error Occurrence condition Occurs if the temperature input circuit is abnormal Release method Repair the board Auto tuning error Occurrence condition Occurs if the temperature sen...

Страница 32: ...TOHO ELECTRONICS INC WEB site http www toho inc com E mail overseas toho inc co jp Head office 2 4 3 Nishihashimoto Midori Ku Sagamihara Shi Kanagawa 252 0131 Japan TEL 81 42 700 2100 FAX 81 42 700 2...

Отзывы: