5-5 Input / Output Receiver
Terminal Block
Terminal #
Description
Features
1
OUT1
Output non-voltage contact signal and LED1 is lit When receiving
completion signal from BL transmitter #1. There is no polarity.
2
3
OUT2
Output non-voltage contact signal and LED2 is lit When receiving
completion signal from BL transmitter #2. There is no polarity.
4
5
RESET
Contact terminal to reset “outputting non-voltage contact signal”
and “auto-reset”. Required to input pulse, more than 0.1 second.
6
7
OUT3
Output non-voltage contact signal and LED3 is lit When receiving
completion signal from BL transmitter #3. There is no polarity.
8
9
OUT4
Output non-voltage contact signal and LED4 is lit When receiving
completion signal from BL transmitter #4. There is no polarity.
10
11
LS IN
When BL torque wrench is down, LS torque wrench can be wired
to LS-IN and COM for back-up.
12
LED light
LED light