Radio Frequency
Torque W
rench with Double
Tightening Detection
7
5. External View and Each Part Name
• Battery cover
Slide it to open the battery case for battery change.
• LED
Blue light in 1 sec.
Red blinks 3 time
Red light up
• TEST button
By pressing shortly, send a signal for communication check between transmitter and receiver or press.
Press and hold it to check battery level.
Blue light up: Battery is enough to use.
Red light up: It is time to replace.
• SET switch
Press it for 1 sec. to move to setting mode for checking or changing the group/judgment code/ID.
Press it for 2 sec. to move to double tightening judgment angle setting mode.
Press it shortly to return to standard mode.
• Channel plate
If channels are specified when you order to Tohnichi, the group and ID will be marked on the plate.
• Plate
If torque set are specified when you order to Tohnichi, the setting torque value and unit will be marked on the
plate.
Battery cover
LED
Plate
TEST button
Channel plate
SET switch
: Communication OK
: Communication error
: Double tightening, it continues until the TEST button or SET switch is pressed or
conduct correct tightening operation.