Страница 1: ...n MODEL CSPFHW Operating Instruction To use this product properly and safely please read this operating instruction carefully before use If you have any question about the product and its operations p...

Страница 2: ...Danger Imminent danger which may cause serious damage Warning Potential danger which may cause serious damage Caution Potential danger which hinder ordinary operation but may not lead to serious dama...

Страница 3: ...se such as PC If the receiver is placed adjacent to the transmitter different groups must be set between the receiver and the transmitter If the receiver where the ID is set on a different channel in...

Страница 4: ...6 1 Caution for correct use 6 2 Instruction for use 6 3 Transmitter battery and communication check 6 4 Battery replacement 6 5 Double tightening judgment angle setting 7 LED Display Messages 8 Settin...

Страница 5: ...he 5ch extracted from 78ch frequencies from 2 402GHz to 2 479GHz 1MHz interval is set as 1 group and there are 256 groups in total ID 000 to 999 and 7 alphanumeric characters can be set With this ID t...

Страница 6: ...s alphanumeric Input Output Non voltage relay output 1a RS232C output RS232C input Power Source DC1 5V AAA alkaline x 1 AC100V 240V 47 63Hz 0 3A DC9V Alkaline x 1 Antenna Chip antenna Dipole antenna D...

Страница 7: ...ss it for 1 sec to move to setting mode for checking or changing the group judgment code ID Press it for 2 sec to move to double tightening judgment angle setting mode Press it shortly to return to st...

Страница 8: ...ll be judged as NG The angle setting can be changed at setting mode The initial setting angle is set at 999 for the double tightening judgment angle Be sure to set it according to the tightening work...

Страница 9: ...at the set torque beyond double tightening judgment angle transmitter sends a tightening completion signal to receiver In case the angle is less than judgment angle and double tightening NG signal is...

Страница 10: ...replacement 3 Communication check will be conducted after releasing the TEST switch and completed battery level check consecutively Power on the receiver that you are going to conduct communication ch...

Страница 11: ...ibration are given during angle checking the LED keeps flashing in red In above case on off the power by remove and insert the battery and restart from the beginning 4 At the settin mode the LED keeps...

Страница 12: ...t on Red blinking Blue blinking 1 sec 1 sec Double tightening judgment error Gyro sensor zero correction error Micro switch error The wrench detected double tightening because the tightening rotated a...

Страница 13: ...he setting sofware to your PC System requirements a OS Windows 7 or later version b Microsoft NET Framework 4 0 or later version If Microsoft NET Framework4 0 or higher is not installed on your PC ref...

Страница 14: ...Detection 4 Click Install Depending on OS system the message Do you want to allow the following program from an unknown publisher to make changes to this computer is displayed Click the Install to pro...

Страница 15: ...g Detection 15 Trademarks Microsoft and Windows are registered trademarks of the Microsoft Corporation 6 When installation has been completed a shortcut icon of Pokayoke Tool Parameter etting Software...

Страница 16: ...t a time If multiple transmitters and receivers are set to the setting mode at the same time they cannot be set correctly PC SB FH2 RS232C Straight Cable 2 Press SET switch on the T FHW transmitter fo...

Страница 17: ...rench with Double Tightening Detection 17 4 If it is not connected automatically make sure that the setting box is power on RS232C cable has been connecting firmly and T FHW is in the setting mode and...

Страница 18: ...18 Radio Frequency Torque Wrench with Double Tightening Detection 5 When Connected appears on the screen select a tab of setting items...

Страница 19: ...when simultaneous transmission is not performed 1 3 digit ID with identification factory setting 2 7 digit alphanumeric characters with identification 3 3 digit ID 7 digit alphanumeric characters wit...

Страница 20: ...g has been occured Available when double tightening NG signal setting is ON By setting the double tightening NG ID to the surplus relay output ports of a receiver it is available to send a NG relay si...

Страница 21: ...ing items and click Send the updated settings will be sent to T FHW via SB FH2 wirelessly Press Get and receive setting to confirm the settings have been changed 8 Setting has been completed Press SET...

Страница 22: ...to the antenna for the receiver move the receiver to a different place There is a shield between the transmitter and the receiver Move the shield or the receiver to a different place Radio wave enviro...

Страница 23: ...86 208 218 291 349 5 445 660 Dimensions m L d3 m n d 193 10 19 9 2 15 214 12 25 5 11 2 20 217 15 290 28 12 2 21 7 348 5 429 19 35 15 27 2 627 22 D Weight kg 29 62 0 32 34 83 5 93 5 0 46 147 5 0 65 169...

Страница 24: ...ohnichi com TOHNICHI AMERICA CORP TEL 1 847 947 8560 FAX 1 847 947 8572 1303 Barclay Blvd Buffalo Grove IL 60089 USA E mail inquiry tohnichi com Website http tohnichi com TOHNICHI SHANGHAI MFG CO LTD...