15
DIGITAL TORQUE WRENCH “DATA TORK” MODEL
CEM3-G
(3) Tightening mode measurement
It informs when torque reaches the target range by buzzer and LED, and alarms when it is out
of the range by another buzzer.
(OK: Upper limit
Measured torque
Lower limit NG: Measured torque > Upper limit,
Lower limit > Measured torque)
Setting (example):
Measurement mode: MODE-T
Upper limit: 55 N·m
Lower limit: 50 N·m
DUAL MODE
LCD MODE
N·m
0.0
09 : 30
001
N·m
001
0.0
Apply torque
N·m
50.0
09 : 30
001
N·m
001
50.0
1. Set the counter to 001-999 (M-3
mode) or 01-99 (M-2 mode).
2. When the applied torque
reaches the lower limit, the
buzzer goes off and green LED
tur ns on. Release torque
before it reaches the upper
limit and push
.
In case of OK
Green LED turns on for 0.5 sec.
Note) If Auto memory/reset is set,
judgement will be given
automatically after the set timing.
Note) When connected to PC or printer,
the measured data will be output.
In case of NG
When the applied torque reaches
the lower limit, green LED turns on.
As it exceeds the upper limit, red
LED turns on to alarm the applied
torque is out of range. As you
push
, buzzer goes off to
give NG judgement.
To save the NG data, press
.
To delete the NG data, press
.
Blue
LED
N·m
50.0
09 : 30
001
N·m
001
50.0
Release torque
N·m
50.0
09 : 30
001
N·m
001
50.0
(In case of OK judgement)
Push MEM for judgement
N·m
60.0
09 : 30
001
N·m
001
60.0
(In case of NG judgement)
When it exceeds the upper limit
Blue
LED
N·m
60.0
09 : 30
001
N·m
001
60.0
Red
LED
Red
LED
When it reaches the lower limit (Buzzer sounds for 0.5 sec)
Push MEM key to give judgement (Buzzer keeps sounding)