59
6.2 The procedure of automatic configuration
Relation of function buttons and LEDs
Function button
Indicator LED #
Mode
Teach
Read
A
B
C
D
Normal Start
setup
mode
Start
reading
Turn ON while
judgment is
output
(need to be
set)
Blink Turn
ON
during serial
communication
(Sending)
Turn ON
during serial
communication
(Receiving)
At the
beginning
of setup
mode
Exit
from
setup
mode
Execute
setup
sequence,
save result
Combination of these LEDs ON/OFF indicates the status of
setup mode.
(
Æ
ON,
Æ
OFF: from left to right “A B C D”)
1) Place the target barcode within the field of view of the unit
2) Press “Teach” button until all LED indicators start blinking (approx. 1 second)
This means the unit is in standby state for automatic setup.
3)
In this state, if “Teach” button is pressed more than 1 second, the unit goes to the
normal mode.
4) Press “Read” button in the state described in 3) more than 1 second, then the unit
start searching the best combination of the reading parameter.
If “Teach” button is pressed more than 1 second while the unit is searching the best
combination, the unit stops searching and go to standby state described in 3).
After that, pressing “Read” makes the unit start searching again.