![TOHATSU VF21BS Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/tohatsu/vf21bs/vf21bs_owners-manual_1124707066.webp)
52
15. SERVICE AND MAINTENANCE
Vacuum pump strainer
Maintenance
・
Incorrect installation of the strainer may cause a vacuum leak. Be
sure to install the strainer correctly.
Refer to “Chapter 11 MAINTENANCE AFTER OPERATION”
1.
Remove the strainer cap, and remove the strainer.
2.
Wash the strainer with fresh water.
3.
After washing, assemble the strainer.
Tighten with the strainer cap.
Engine oil
Check the oil level
・
Confirm the filler cap closed tightly
each time, whenever you check the
oil level.
Check the oil level after each operation.
1.
Place the pump in a horizontal location.
2.
Check the oil level.
3.
Refill the oil until the “UPPER” level.
・
4-stroke engine oil
SAE 10W-30/40 of SF, SG, SH, SJ, SL
and SM series of API classification
Vacuum pump strainer
case
Strainer cap
NOTE
Oil filler cap
Upper
Lower
CAUTION
NOTE