6
Hour Meter
Figure 2-3. Hour Meter
Connection Plugs
0.0
Figure 2-4. 120 VAC, 20 Amp, Duplex
Receptacle NEMA 5-20R
The Hour Meter tracks hours of operation for
scheduled maintenance. See
Figure 2-3
.
NOTE
: The hour glass icon will flash when the
engine is running. This signifies the meter is
recording hours of operation
The 120 Volt outlet is overload protected by a 20
Amp push-to-reset circuit breaker. See
Figure 2-4
.
Each receptacle will power 120 Volt AC, single
phase, 60 Hz electrical loads requiring up to 2400
watts (2.4 kW) or 20 Amps of current. Use only high
quality, wellinsulated, 3-wire grounded cord sets
rated for 125 Volts at 20 Amps (or greater).
120 VAC, 20 Amp, Duplex
Receptacle
120 VAC, 30 Amp Receptacle
Use a NEMA L5-30 plug with this receptacle (rotate
to lock/unlock). Connect a suitable 3- wire cord set
to the plug and to desired load. The cord set should
be rated for 125 Volts AC at 30 Amps (or greater).
See
Figure 2-5
. Use this receptacle to operate 120
Volt AC, 60Hz, single phase loads requiring up to
3000 watts (3.0kW) of power at 25 Amps. The outlet
is protected by a 25 Amp circuit breaker.
1. Open carton completely by cutting each corner
from top to bottom.
2. Remove and verify carton contents prior to
assembly. Carton contents should contain the
following:
Figure 2-5. 120 VAC, 30 Amp Receptacle
Remove Contents from Carton
Owner’s Manual for Petrol Generator