Installation Instructions
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
These instructions cover the basic principles to ensure satisfactory installation of the stove and cannot
cover all situations due to the site of location conditions. In all cases the installation must comply with
National and European Building Regulations, Local Authority Byelaws and other specifications or
regulations as they affect the installation of the stove.
Health and Safety Precautions
Handling
Adequate facilities must be available for unloading and site handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In
case of contact, wash immediately with plenty of water.
Metal Parts
When installing or servicing the stove, take care to avoid the possibility of personal injury.
Note:
Any white deposits on the stove joints are caused by humidity reacting with the joint sealant. These
deposits may be brushed off and, if necessary, blackened with a proprietary stove polish.
Important Warning
This stove MUST NOT
be installed into a chimney that is shared with any other heating appliance.
No purpose provided ventilation is required for stoves rated under 5kW. For each kW above 5kW, 550
mm
2
of fixed ventilation is required i.e. a stove rated at 8kW would require 3 x 550 mm
2
= 1650 mm
2
of fixed ventilation.
If more than one appliance is installed in the same room, the ventilation requirements for each
appliance must be added together.
There MUST NOT be an extractor fan fitted in the same room as the stove as this can cause the stove
to emit fumes into the room.
Installation
Chimney
The chimney must be fitted in accordance with manufacturer’s instructions and the relevant part of the
Building Regulations. The chimney height and the position of the chimney terminal should conform to
Building Regulations. Check that the chimney is in good condition, dry, free from cracks and
obstructions. The diameter of the flue should not be less than 125mm and not more than 200mm. If any
of these requirements are not met, the chimney should be lined by a suitable method. The chimney
must be swept before connection to the stove.
Where the chimney is believed to have previously served as an open fire installation, it is possible that
the higher flue gas temperature from the stove may loosen deposits that were previously securely in
place, with the possible risk of flue blockage. It is therefore recommended that the chimney be swept a
second time within a month of regular use after installation. If you have any doubts about the suitability
of your chimney, consult a local installer.
Flue Draught