Toastie Woodburners ELDUR Скачать руководство пользователя страница 11

11 

 Ref: 14/ST/BF/1 

Fire difficult to start 
Fire goes out 

Logs are too big 

To light the fire, use small & very dry 
twigs. To maintain the fire, use split 
logs. 

Lack of air 

Open lower spin wheel and top air 
control lever 

Insufficient draught 

Check that the flue is not blocked; 
sweep it if necessary. Seek advice from 
a chimney specialist 

Fire burns too quickly 

Too much draught 

Ensure that the lower spin wheel is 
closed. 
Partially close the top air control lever. 

Excessive draw 

Install a draught stabilizer. Consult a 
qualified installer 

Poor quality wood 

Do not continuously burn small wood, 
Sticks, bundles, carpentry off-cuts 
(plywood, pallets), etc. 

Smokes when lighting up 

Flue duct is cold 

Burn paper and kindling wood to 
increase heat. 

Room is in decompression 

Houses equipped with mechanical 
ventilation, partly open a window until 
the fire is well established. 

Smokes while burning 

Draught is insufficient 

Consult a chimney specialist. 
Check that the flue is not obstructed, 
Sweep if necessary. 

Down draught 

Houses equipped with mechanical 
ventilation, should partly open a 
window until the fire is well established. 

Low heat output 

Incorrect Fuels 

Use the recommended fuel. 

Содержание ELDUR

Страница 1: ...tructions IMPORTANT Installation MUST ONLY be carried out by a Gas Safe registered engineer installer Please read this user s Installation and Operating Instructions fully before installation and oper...

Страница 2: ...OFNI 5KW ELDUR 6KW List of Components Description of Parts Stove parts Accessories 1 Ashpan 1 11 Glove 1 2 Coal Guard 1 12 Brush 1 3 Ashpan tool 1 4 Legs 4 5 Leg Height Screws 4 6 Leg Washers 4 7 Baff...

Страница 3: ...ARE REQUIRED TO MOVE THE CRATE AND STOVE 1 Remove the outer packaging A Carefully remove the packing straps and lift off the upper crate B Remove the plastic bag and take down the stove from the bott...

Страница 4: ...ve the fitted Flue Cover and refit on the rear opening 4 To fit the Baffle Insert the baffle upside down as shown ensuring you are holding the shorter of the two sides Turn the baffle as you fit it so...

Страница 5: ...For each kW above 5kW 550 mm2 of fixed ventilation is required i e a stove rated at 8kW would require 3 x 550 mm2 1650 mm2 of fixed ventilation If more than one appliance is installed in the same roo...

Страница 6: ...and top and at least 50mm at the back of the stove to obtain maximum heat output and for access to the rear of the stove All non combustible walls closer than 400mm to the stove should be at least 75...

Страница 7: ...stove is fitted with an air wash system This secondary air supply to the stove is controlled through a slider assembly located at the top of the stove Note The secondary air control is open when push...

Страница 8: ...ble it to dry out Burning wet or unseasoned wood will create tar deposits in the stove and chimney and will not produce a satisfactory heat output Lighting the Stove It is recommended to get the best...

Страница 9: ...ch for signs of overfiring if any part of the stove starts to glow red the fire is in an overfire situation and the controls should be adjusted to immediately prevent the overfiring WARNING FUME EMISS...

Страница 10: ...fibreglass rope is used on the stoves Inspect the rope around the door and glass If rope is becoming detached use a proprietary rope glue to reattach it Ensure you replace the rope in the case of it...

Страница 11: ...draught stabilizer Consult a qualified installer Poor quality wood Do not continuously burn small wood Sticks bundles carpentry off cuts plywood pallets etc Smokes when lighting up Flue duct is cold B...

Отзывы: