Toa VP-1061 Скачать руководство пользователя страница 4

4

2. GENERAL DESCRIPTION

The VP-1061 (60 W), VP-1121 (120 W), VP-1241 (240 W), and VP-1361 (360 W) are 1-channel Power
Amplifiers designed exclusively for rack mount use.

3. FEATURES

• Both the VP-1061 and VP-1121 are 2U* half rack size amplifiers, mountable either alone or side-by-side in a

19" rack. 

• Both the VP-1241 and VP-1361 are 3U* full rack size amplifiers.

• Operate on either 230 V AC or 24 V DC.

• An optional YA-1000A Fault Detection Circuit Module can be installed.

• Equipped with Program and Priority inputs, volume level of Program input can be attenuated whenever the

Priority input receives a signal. Attenuation of the volume level is adjustable.

• Input terminals employ removable terminal blocks to provide maximum connection ease.

* 1U size = 44.5 mm (standard size)

4. HANDLING PRECAUTIONS

• It is recommended that the unit be always used in locations where the ambient temperature ranges from 0 to

+40 °C and humidity is less than 90% (no condensation). 

• When cleaning the unit, be sure to disconnect the power supply plug from the AC outlet. Wipe with a soft dry

cloth. If it gets very dirty, use the soft cloth slightly moistened in neutral cleanser. Never use thinner,
benzene, chemically processed towels, or alcohol as the unit's plastic or other parts may be deformed or
discolored.

• When moving the unit, be sure to remove its power

supply cord from the AC outlet. Moving the unit
with the power supply cord connected to the outlet
may cause damage to the power supply cord,
resulting in fire or electric shock. When removing
the power cord, be sure to hold its plug to pull.

• Do not block the ventilation slots in the unit's cover.

Doing so may cause heat to build up inside the unit
and result in fire.

• Avoid installing the unit in humid or dusty locations,

in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.

• When unpacking or moving the unit, be sure to

handle it with two or more persons. Falling or
dropping the unit may cause personal injury and/or
property damage.

• To avoid electric shocks, be sure to disconnect the

power supply plug from the AC outlet when
connecting speakers.

• Be sure to follow the instructions below when rack-

mounting the unit. Failure to do so may cause a fire
or personal injury.
· Install the equipment rack on a stable, hard floor. 

Fix it with anchor bolts or take other arrangements

to prevent it from falling down.

· When connecting the unit's power cord to an AC

outlet, use the AC outlet with current capacity
allowable to the unit.

When the Unit is in Use 

• Make sure that the volume control is set to

minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.

• Do not operate the unit for an extended period of

time with the sound distorting. Doing so may cause
the connected speakers to heat, resulting in a fire.

• Contact your TOA dealer as to the cleaning. If dust

is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result.

• If dust accumulates on the power supply plug or in

the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.

• Unplug the power supply plug from the AC outlet

for safety purposes when cleaning or leaving the
unit unused for 10 days or more. Doing otherwise
may cause a fire or electric shock. 

Содержание VP-1061

Страница 1: ...1 60 W VP 1121 120 W VP 1241 240 W VP 1361 360 W Thank you for purchasing TOA s Power Amplifier Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment OPERATING INSTRUCTIONS ...

Страница 2: ...IONS 6 1 Front 5 6 2 Rear 6 7 RACK MOUNTING 8 8 REMOVABLE TERMINAL PLUG CONNECTION 9 9 CONNECTIONS 9 1 Connecting to an AC Power Source 10 9 2 Connecting to a DC Power Supply 10 9 3 Speaker Connection 10 9 4 Attenuator Connection 10 10 DIMENSIONAL DIAGRAM 10 1 VP 1241 VP 1361 11 10 2 VP 1061 VP 1121 11 11 SPECIFICATIONS 12 Accessories 12 Optional Products 12 ...

Страница 3: ...s into the unit If the unit falls or the unit case breaks If the power supply cord is damaged exposure of the core disconnection etc If it is malfunctioning no tone sounds To prevent a fire or electric shock never open nor remove the unit case as there are high voltage components inside the unit Refer all servicing to qualified service personnel Do not place cups bowls or other containers of liqui...

Страница 4: ...t s cover Doing so may cause heat to build up inside the unit and result in fire Avoid installing the unit in humid or dusty locations in locations exposed to the direct sunlight near the heaters or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock When unpacking or moving the unit be sure to handle it with two or more persons Falling or dropping ...

Страница 5: ...iority input 18 volume Turn the control clockwise to increase the volume and counterclockwise to decrease it 5 Priority input Fault indicator Lights green while the Priority control input terminals 17 are shorted Lights red when the fault detection circuit is activated Operates when the YA 1000A is mounted VP 1061 VP 1121 5 INSTALLATION PRECAUTIONS Avoid using the power supply cord other than the ...

Страница 6: ...to the unit Connecting the case terminal to the functional ground terminal of the external equipment may reduce the hum noise A ground lift jumper is factory set between the Case and Circuit terminals When this jumper is removed the circuit ground can be electrically disconnected Note This ground is not for protective ground 10 24 V DC Power input terminals Connect to 24 V DC power supply 11 Emerg...

Страница 7: ...r the one through the Program input 15 while the Priority control input 17 terminals are shorted 19 Priority control output terminals These terminals are internally connected in parallel to the Priority control input terminals 17 20 Priority output terminals These terminals are internally connected in parallel to the Priority input terminals 18 Connecting these terminals to the other amplifier s i...

Страница 8: ... Secure the Joint Bracket supplied with the MB 25B J to the bottom sides of the units using 2 supplied tapping screws 3 x 8 Step 2 Secure the supplied joint bracket to the units rear panels using 2 supplied tapping screws 3 x 8 Step 3 Secure the supplied joint bracket to the units top panels using 2 supplied tapping screws 3 x 8 Step 4 Attach one Mount Bracket to the side of each unit as shown at ...

Страница 9: ...sive rise in joint temperatures Usable cables of AWG 16 28 Cable end treatment Shielded cable 7 mm 20 mm When mounting 2 or more units in an equipment rack be sure to mount a perforated panel larger than 1U size above every 2 stacks of amplifiers as shown in the figure 1U size 44 5 mm standard size It is recommended that a supporting runner be installed to the rack so that the unit can be easily d...

Страница 10: ...broadcast attenuators can be connected using either of the following two methods 3 wire system 4 wire system Use the DC power cable of AWG 16 or thicker VP 1061 and VP 1121 or AWG 12 or thicker VP 1241 and VP 1361 Also be sure to firmly screw the cable to the terminal Failure to do so may cause the cable to generate heat possibly resulting in fire 9 2 Connecting to a DC Power Source When using a 2...

Страница 11: ...11 10 DIMENSIONAL DIAGRAMS 10 1 VP 1241 VP 1361 Unit mm 483 6 465 37 7 57 2 132 6 337 8 320 5 10 2 VP 1061 VP 1121 210 88 4 338 7 321 5 ...

Страница 12: ...4 W 19 W 21 W 37 W DC at rated output 4 5 A 8 2 A 14 6 A 20 9 A DC no signal 0 1 A 0 1 A 0 4 A 0 5 A Rated Output 60 W 120 W 240 W 360 W Input 2 Program inputs parallel 0 dB 20 kΩ balanced 2 Priority inputs parallel 0 dB 20 kΩ balanced Impedance 167 Ω 83 Ω 42 Ω 28 Ω S N Ratio 80 dB or more Total Harmonic Distortion 1 or less at rated output f 1 kHz Frequency Response 80 Hz 16 kHz 3 dB at 1 3 rated...