OPERATION

Press the A channel  key to select the A channel.

The A channel indicator comes on, while both the date and clock

mode indicators flash.

Put the timer in the day mode by pressing the DAY mode key.

The day mode indicator comes on and at the same time, day

indicators from Monday to Sunday flash.

Press the CHECK key.

The indicator of the registered day of the week comes on.

....... To step (9) to change  the day of the

week.

....... To step  (10) to cancel the day of the

week.

Press the TIME mode key.

The time mode indicator comes on and at the same time, a

dotted line "   –  –  –  –  " flashes in the clock display.

Check the  hour.

Each time the CHECK key is pressed, the registered  hour is

shown in the clock display starting first with the earliest hour to

the latest in sequence. Pressing the check key when the last

hour is indicated causes the word "End" to appear in the clock

display,  returning the indication to the first hour.

Move to the next step to cancel the registered hour.

..... To step (8) to correct hour.

A

DAY

CHECK  I

TIME

CHECK

10

All manuals and user guides at all-guides.com

Содержание TT-104B

Страница 1: ...and precisely through individual key operation and display Setting the pause mode allows no program output to be delivered Output is a no voltage make contact that connects for five seconds at the pr...

Страница 2: ...Program check correction and cancellation 5 Entire program cancellation 6 Program operation 7 Pause mode 8 Using front mounted AUTO OFF switch 9 Using manual switch 10 Using rear mounted channel assig...

Страница 3: ...ys Use this keys to set a clock for the current hour To do this press this setting with the ADJUST key pressed continuously This setting is also used to set the time of the timer program Each time the...

Страница 4: ...upplied with unit Write the names of programs of or equipment connected to each output channel in the label STORE key Press this key to store the day of the week or hours set under the day time or pau...

Страница 5: ...ayer or spot announcing machine etc MEMORY BACK UP switch Be sure to set this switch to ON after installation This switch protects clock and stored programs for approximately 100 hours during power ou...

Страница 6: ...is not in a range from zero hour 00 00 to 23 hundred 59 hours 23 59 both the date indicator and clock display flash and at the same time a warning tone beeps In such a case correct the hour 5 Press th...

Страница 7: ...quipment connected and assign the output channel to each equipment If the same equipment are used but their programs are not the same assign different output channels Example If it is so programed as...

Страница 8: ...omes on Press the THU setting Its indicator comes on Press the FRI setting Its indicator comes on MON TUE WED THU FRI When the wrong day setting has been pressed press the same setting again and the c...

Страница 9: ...the STORE key to register the unreal hour other than one from 00 00 to 23 59 causes characters Err to appear in the clock display and the attempt of its registration is refused Correct the hour and re...

Страница 10: ...p 10 to cancel the day of the week Press the TIME mode key The time mode indicator comes on and at the same time a dotted line flashes in the clock display Check the hour Each time the CHECK key is pr...

Страница 11: ...ay Press the CANCEL key for cancelling the indicated hour and then set the new hour using the clock settings Register the new hour with the STORE key Be sure to cancel the previous hour when correctin...

Страница 12: ...The PAUSE key is used to temporarily make the timer not to function on particular days This is possible for up to the 7th day from the day of registration No output is delivered from the timer on a da...

Страница 13: ...pause registration perform the new pause registration Set the program switch to OPERATION after finishing programing USING FRONT MOUNTED AUTO OFF This switch is used to stop actions of an output rela...

Страница 14: ...h channel as follows A 8 30 9 30 10 30 B 9 00 10 00 11 00 C 12 00 If all the switches are set to OFF A channel Output is delivered at 8 30 9 30 and 10 30 B channel Output is delivered at 9 00 10 00 an...

Страница 15: ...amination day program 1 register the ordinary school hour program into the A channel Register Monday through Friday 2 register the Saturday program into the B channel Register Saturday 3 register the...

Страница 16: ...utage However a clock works normally and stored programs are protected No relay output is produced After power restoration the timer works normally and indicates the current hour 2 A clock and stored...

Страница 17: ...ours 30 steps per channel Day of the week hour minute output channel 4 channels A B C D No voltage dry make contact 5 seconds make output 24 V DC 0 5 A 5 seconds per month 25 C Day of the week hour mi...

Страница 18: ...TOA Corporation Printed in Japan 133 05 276 50 All manuals and user guides at all guides com...

Отзывы: