![Toa SX-2000CI Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/toa/sx-2000ci/sx-2000ci_operating-instructions-manual_1122560012.webp)
12
[Connections]
It is recommended to use an optional RM-200RJ Terminal Unit that serves wiring conversion between the
CPEV cable and STP Category 5 straight cable (with RJ45 connectors). Connect the CPEV cable between
the same terminals of both RM-200RJ units pairing cables 3 with 6, 4 with 5, and 7 with 8 as shown below.
Terminals 4 and 5 serve to supply power to B channel.
44.5
11
6
44.5
13.5
75
84
SX-2000CI
SX-2000CO
AD-011
Note:
The RM-200RJ can be installed on a desk or to a wall.
STP Category 5 straight cable
(with RJ45 connectors)
STP Category 5 straight cable
(with RJ45 connectors)
Unit: mm
AD-011
DC power supply panel
AWG14 – 18
AWG14 – 18
AWG14 – 18
AWG14 – 18
Over 3-pair shielded
CPEV cable (main cable)
terminal unit
RM-200RJ
RM-200RJ
DC power
input terminal
DC power
input terminal
CI/CO link
data terminal
CI/CO link
data terminal
[RM-200RJ Mounting dimensions]
24VDC OUT
24VDC IN
24VDC OUT
24VDC IN
5
4
7
8
7
8
7
8
Shield
5
4
7
8
Shield
6
3
6
3
5
4
5
4
Note:
When using the AD-031B DC power supply panel (optional),
make connections in the same manner.
Note
Terminals 1 and 2
cannot be used for
power supply line.