Toa SX-2000CI Скачать руководство пользователя страница 1

OPERATING INSTRUCTIONS

CONTROL INPUT UNIT
CONTROL OUTPUT UNIT

SX-2000CI
SX-2000CO

1. SAFETY PRECAUTIONS 

........................... 2

2. GENERAL DESCRIPTION 

......................... 3

3. NOMENCLATURE AND FUNCTIONS

3.1. SX-2000CI Control Input Unit ............... 4
3.2. SX-2000CO Control Output Unit .......... 6

4. CONNECTIONS 

4.1. Removable Terminal Plug 

Connection ........................................... 8

4.2. Connection Example ............................ 9
4.3. Power Supply Connections ................ 10

4.4. Control Input Connections

(SX-2000CI Only) ............................... 14

4.5. Control Output Connections

(SX-2000CO Only)  ............................. 14

4.6. CI/CO Link Terminal Connections ...... 15

5. SETTINGS

5.1. Stand-Alone Mode Setting ................. 15
5.2. Priority Control Settings of the Control 

Inputs (SX-2000CI Only) .................... 16

6. SPECIFICATIONS 

6.1. SX-2000CI Control Input Unit ............. 19
6.2. SX-2000CO Control Output Unit ........ 20

Thank you for purchasing TOA's Control Input Unit and Control Output Unit. 
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

TABLE OF CONTENTS

1

9

2

10

3

11

4

12

5

13

6

14

7

15

8

16

POWER

CPU OFF

FAULT

CONTROL INPUT UNIT  SX-2000CI

17

25

18

26

19

27

20

28

21

29

22

30

23

31

24

32

CONTROL INPUT

SX-2000CI

SX-2000CO

1

9

2

10

3

11

4

12

5

13

6

14

7

15

8

16

POWER

CPU OFF

FAULT

CONTROL OUTPUT UNIT  SX-2000CO

17

25

18

26

19

27

20

28

21

29

22

30

23

31

24

32

CONTROL OUTPUT

FOR STAND-ALONE MODE

Note

Two modes of operation are made available for the SX-2000CI and SX-2000CO: Normal mode
where the unit operates within the SX-2000 system and Stand-alone mode where the unit
operates independently of the SX-2000 system.
This book provides instruction when the SX-2000CI and SX-2000CO are used in stand-alone
mode.
When using them in normal operation mode, refer to the instruction manual enclosed with the
SX-2000SM System Manager of the SX-2000 series.

Содержание SX-2000CI

Страница 1: ...trol Output Unit Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment TABLE OF CONTENTS 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 POWER CPU OFF FAULT...

Страница 2: ...wise may result in fire or electric shock SX 2000CI and SX 2000CO are designed exclusively to be mounted in an equipment rack Be sure to follow the instructions below when rack mounting the unit Failu...

Страница 3: ...ts the contact data of multiple channels to be transmitted to the remote locations with simple wiring The front mounted indicators of each unit show the control input status or control output status T...

Страница 4: ...ed This indicator is not used 4 FAULT Indicator FAULT Yellow Lights when communications with the connected SX 2000CO are interrupted 5 USB Port USB This port is not used 6 RUN Indicator RUN Green Norm...

Страница 5: ...ystem from going down when a cable is broken or power fails 12 24 V DC Output Terminal DC 24 V OUT This terminal supplies 24 V DC max 100 mA to connected external equipment 13 Control Input Terminals...

Страница 6: ...ights when the power is switched on 3 CPU OFF Indicator CPU OFF Red This indicator is not used 4 FAULT Indicator FAULT Yellow Lights when communications with the connected SX 2000CI are interrupted 5...

Страница 7: ...connecting the commercial power supply and backup power supply separately to each power input to prevent the system from going down when a cable is broken or power fails 12 Control Output Terminals C...

Страница 8: ...ews Ensure that the wire does not break free when pulled If the wire does pull free repeat the connection procedure from the start Step 2 Insert the wired terminal plug into the corresponding terminal...

Страница 9: ...2000CO separately See p 11 and 15 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 POWER CPU OFF FAULT CONTROL INPUT UNIT SX 2000CI 17 25 18 26 19 27 20 28 21 29 22 30 23 31 24 32 CONTROL INPUT 1 9 2 10 3 11 4...

Страница 10: ...is still supplied from the other unit preventing the system from going down DC 24V OUT MAX 0 1A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 CONTROL ON OFF CI...

Страница 11: ...supply panels to the SX 2000CI only Connect the DC power input terminals of the SX 2000CI to those of the SX 2000CO and the CI CO link data terminals of the SX 2000CI to those of the SX 2000CO via th...

Страница 12: ...lled on a desk or to a wall STP Category 5 straight cable with RJ45 connectors STP Category 5 straight cable with RJ45 connectors Unit mm AD 011 DC power supply panel AWG14 18 AWG14 18 AWG14 18 AWG14...

Страница 13: ...n the power is supplied from the SX 2000CI side refer to the table on p 11 Connections It is recommended to use an optional RM 200RJ Terminal Unit that serves wiring conversion between the CPEV cable...

Страница 14: ...rent 2 mA 16P removable terminal plug supplied with the SX 2000CI Cable AWG22 28 twisted pair cable Control input terminals OUTPUT CHANNEL 24 V DC 0 5 A 4 5 Control Output Connections SX 2000CO Only T...

Страница 15: ...ta terminal Factory preset OFF CI CO link through switch OFF Factory preset OFF ON OFF CI CO LINK THROUGH DATA CI CO LINK THROUGH DATA ON OFF The SX 2000CI and SX 2000CO can be connected using the shi...

Страница 16: ...G ON SETTING ON Step 3 Set the link through switch on the SX 2000CI CO s rear panel to the OFF position Note The CI CO link through switch is set to OFF by default SX 2000CI rear DC 24V OUT MAX 0 1A 1...

Страница 17: ...erminal number of the control input the higher the priority level For example closing the control input 1 while the control input 2 is closed causes the control output 2 to open Opening the control in...

Страница 18: ...100 ms Control input 1 Closed Closed Open Control input 2 Control output 1 Closed Closed Closed Open Open Control output 2 5 2 4 First in first out DIP switch 3 ON DIP switch 4 ON The first control in...

Страница 19: ...power supply to each unit 1 pair for data line When connecting the power supply only to the SX 2000CI 1 pair data line and 2 pair power line for a redundant power supply system or 1 pair data line and...

Страница 20: ...1 pair data line and 1 pair power line for a non redundant power supply system Branch cable STP Category 5 straight cable Maximum Cable Distance 800 m Maximum Delay Time 300 ms Operating Temperature...