5. INSTALLATION

The N-8000CO can be installed in any of three ways: Equipment rack mounting, Desk-top installation, and Wall 

mounting.

5.1. Equipment Rack Mounting

A)  Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient 

temperature of the rack environment may be greater than room ambient. Therefore, consideration should 

be given to installing the equipment in an environment compatible with the maximum ambient temperature 

(Tma) specified by the manufacturer.

B)  Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required 

for safe operation of the equipment is not compromised.

C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is 

not achieved due to uneven mechanical loading.

D) Circuit  Overloading  -  Consideration  should  be  given  to  the  connection  of  the  equipment  to  the  supply 

circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. 

Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention 

should be given to supply connections other than direct connections to the branch circuit (e.g. use of power 

strips)."

A)   Température  ambiante  élevée  -  si  l’appareil  est  installé  dans  un  bâti  fermé  ou  en  même  temps  que 

d’autres appareils, la température à l’intérieur risque de devenir supérieure à la température ambiante. Par 

conséquent, veiller à installer l’équipement dans un environnement compatible à la température ambiante 

maximum spécifiée par le fabricant. 

B)    Débit d’air réduit - L’installation de l’équipement en bâti ne doit pas compromettre le débit d’air nécessaire à 

une utilisation sûre de l’équipement. 

C)   Charge mécanique - Le montage de l’équipement en bâti ne doit pas entraîner de danger dû à une surcharge 

mécanique inégale. 

D)   Surcharge  du  circuit  -  rester  vigilant  lors  de  la  connexion  de  l’équipement  au  circuit  d’alimentation  et 

aux  conséquences  d’une  surcharge  des  circuits  sur  la  protection  contre  les  surintensités  et  les  câbles 

d’alimentation. Tenir compte des indications de la plaque nominale de l’appareil.

E)   Veiller  à  toujours  garantir  l’intégrité  de  la  prise  de  mise  à  la  terre.  Faire  particulièrement  attention  aux 

connexions d’alimentation en dehors des branchements directs au circuit de dérivation (par exemple à l’aide 

de multiprises). 

The N-8000CO can be mounted on the CR-273 or CR-413 or standard EIA 19" Equipment rack.

For the CR-273 and CR-413 Equipment rack assembly, read the installation manual supplied with the rack.

Note

When installing the N-8000CO, lay the equipment rack down face-up to do installation work safely. 

5.1.1. Setting space

For maintenance works, allow much space between the wall and 

Equipment rack.

N-8000CO

50 cm

50 cm

1 m

50 cm

Содержание N-8000CO

Страница 1: ...free use of your equipment 1 SAFETY PRECAUTIONS 2 2 GENERAL DESCRIPTION 6 3 FEATURES 7 4 NOMENCLATURE AND FUNCTIONS 7 Front 7 Rear 7 5 INSTALLATION 8 5 1 Equipment Rack Mounting 8 5 2 Desk Top Instal...

Страница 2: ...mpt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object gets into the unit If the...

Страница 3: ...et contacter le repr sentant TOA le plus proche Ne pas essayer pas d utiliser l appareil dans ces conditions sous peine de provoquer un incendie ou une lectrocution D tection de fum e ou d une odeur...

Страница 4: ...e company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible A...

Страница 5: ...analog content and billing protection affidavit be provided the telephone company Customer instructions must contain information on the preparation and submission of the affidavit Systems The consume...

Страница 6: ...thority or electrician as appropriate To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord Notification for Europe NOTICE The interconnected telecommunication terminal e...

Страница 7: ...inlet Connect the supplied power cord Note If there is a danger of lightning strikes insert an appropriate surge arrester into the power line 10 Subscriber Line Connection Terminal C O LINE Connect t...

Страница 8: ...power strips A Temp rature ambiante lev e si l appareil est install dans un b ti ferm ou en m me temps que d autres appareils la temp rature l int rieur risque de devenir sup rieure la temp rature am...

Страница 9: ...delle en fibre pour M5 2 Vis de montage en b ti 5 x 12 2 Vis de m canique 3 x 12 2 Coupleur 2 Patte de montage 2 Vis taraud 3 x 14 2 Use the optional MB 15B J hardware set when mounting 2 units Utilis...

Страница 10: ...ssory Machine screw M3 x 8 accessory Vis de m canique M3 x 8 accessoire Pied en plastique accessoire When installing the N 8000CO on a desk secure the supplied plastic feet to the unit s bottom using...

Страница 11: ...short as possible Remarque Protection contre les ruptures d alimentation prise d alimentation D verrouillez le collier cordon et glissez y le cordon d alimentation Le c ble entre la prise d alimentati...

Страница 12: ...interface unit Note The Interface Unit s DC resistance is 352 maximum Depending on line resistance conditions the unit might not be usable 1 Select an appropriate UPS taking into consideration the to...

Страница 13: ...8000CO 2 C O line connection Connect the C O line to the PSTN public switched telephone network using the supplied mini clamp connector Refer to p 14 Connector Connection To reduce the rick of fire us...

Страница 14: ...ace Cover transparent side Cable Mini clamp connector accessory model 232D 02S1B DA5 manufactured by DDK Ltd Rear panel 6 2 Type of Cable The types of cables are to be determined according to the foll...

Страница 15: ...g maintenance use 1 Mini clamp connector 2P 2 Plastic foot 4 Machine screw M3 x 8 4 Rack mounting bracket MB 15B BK for rack mounting one N 8000CO unit MB 15B J for rack mounting two N 8000CO units Wa...

Страница 16: ...for Europe Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Europe GmbH Suederstrasse 282 20537 Hamburg Germany URL https www...

Отзывы: