5
3. CONNECTION
3.1. Connection Presets
The unit is factory-preset as follows:
Username: admin
Password: guest
IP address:
192.168.14.1
Subnet mask: 255.255.255.0
Default gateway: 192.168.14.254
Before connecting a PC to the IP horn speaker and changing its setting, it will be necessary to set the PC's
network settings so that it can operate on the same network as the IP horn speaker. Take care that no IP
addresses are duplicated in the same network. For example, if the IP horn speaker's IP address is 192.168.14.1,
set the PC's IP address to 192.168.14.10 or the like.
3.2. Making Connection
Notes
• Avoid simultaneously connecting to the IP horn speaker from multiple PCs.
• Avoid simultaneously connecting to the IP horn speaker from a single PC using multiple browsers.
Step 1. Connect both the unit and the PC to be used for setup to the network.
Step 2. Start the PC's browser and enter the unit's IP address in the address field.
Example: 192.168.14.1
The Login screen will be displayed.
Tip
Default IP address: 192.168.14.1
Step 3. Enter both the username and the password, and click on the
LOGIN button.
The Status screen will be displayed.
Click on the individual function names arranged on the left side
of the browser screen to switch screens and perform the required
settings for each selected screen.
3