1. SAFETY PRECAUTIONS

• Before installation or use, be sure to carefully read all the instructions in this section for 

correct and safe operation.

• Be sure to follow all the precautionary instructions in this section, which contain important 

warnings and/or cautions regarding safety.

• After reading, keep this manual handy for future reference.

Indicates a potentially hazardous situation which, if mishandled, 

could result in death or serious personal injury.

WARNING

Indicates a potentially hazardous situation which, if mishandled, could 

result in moderate or minor personal injury, and/or property damage.

CAUTION

WARNING

When Installing the Unit
• Do  not  expose  the  unit  to  rain  or  an 

environment where it may be splashed by 

water  or  other  liquids,  as  doing  so  may 

result in fire or electric shock. 

When the Unit is in Use 
• Should  the  following  irregularity  be  found 

during use, immediately cut off the power 

supply from a PoE+ or PoE switching hub 

and contact your nearest TOA dealer. Make 

no further attempt to operate the speaker 

in this condition as this may cause fire or 

electric shock. 
· If  you  detect  smoke  or  a  strange  smell 

coming from the unit

· If water or any metallic object gets into the 

unit 

· If the unit falls, or the unit case breaks 

· If the LAN cable is damaged (exposure of 

the core, disconnection, etc.)

· If the speaker suddenly stops producing 

sound

• To  prevent  a  fire  or  electric  shock,  never 

open  nor  remove  the  unit  case  as  there 

are  high  voltage  components  inside  the 

unit. Refer all servicing to qualified service 

personnel.

• Do not touch the unit and LAN cable during 

thunder and lightning, as this may result in 

electric shock.

• To prevent the electromagnetic wave from 

badly influencing medical equipment, make 

sure  to  switch  off  the  unit's  power  when 

placing it in close proximity to the medical 

equipment.

CAUTION

When Installing the Unit
• Avoid installing the unit in humid or dusty 

locations, in locations exposed to the direct 

sunlight,  near  the  heaters,  or  in  locations 

generating sooty smoke or steam as doing 

otherwise  may  result  in  fire  or  electric 

shock. 

• Avoid touching the unit's sharp metal edge 

to prevent injury.

Содержание IP-A1AF

Страница 1: ...sting 5 4 3 Local Broadcasting 5 5 DIMENSIONAL DRAWINGS 6 6 NOMENCLATURE AND FUNCTIONS 7 7 HANDLING PRECAUTIONS 8 8 UNIT MOUNTING 9 9 CONNECTIONS 9 9 1 Network Connection 9 9 2 Connections to LINE MIC...

Страница 2: ...st TOA dealer Make no further attempt to operate the speaker in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any meta...

Страница 3: ...its for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commer...

Страница 4: ...oadcast locally to the speaker output and the LINE output from the sound source device or microphone connected with LINE MIC input Orders of priority can be set among the various broadcasting modes me...

Страница 5: ...l be half duplex LAN VMS software IP A1AF VMS broadcasting Speaker output Low impedance speaker Microphone input Microphone for sound collection Monitoring with audio LINE MICIN IP AUDIO INTERFACE IP...

Страница 6: ...SIGNAL STATUS SPEAKER CLASS 2 WIRING C blage de classe 2 8 16 127 4 5 02 126 4 96 4 M3 depth 6 mm or 0 24 80 3 15 4 0 16 3 5 0 14 13 0 51 12 5 0 49 3 6 0 14 16 5 0 65 40 1 57 20 0 79 33 1 3 104 4 09...

Страница 7: ...reen Lights green when a signal is outputting from the speaker or line output 5 Speaker output terminal 8 16 Connects only with low impedance speakers Tip Amplifier rated output is as follows 8 W at P...

Страница 8: ...Default setting LINE PAD switch Switch 2 Enables or disables the MIC input pad When the input level is high set the PAD to 20 dB Default setting 0 dB PHANTOM switch Switch 3 Set whether or not to supp...

Страница 9: ...cially available L shaped bracket etc and fix it with the accessory screws using the four screw holes of this unit IP A1AF Rubber foot accessory Plate thickness 1 to 3 mm 0 04 to 0 12 Machine screw M3...

Страница 10: ...e a 2 core shielded cable to connect the audio device For connection of the removable terminal plugs see Removable Terminal Plug Connections on p 12 Set the DIP switch according to the audio device to...

Страница 11: ...ine of 2 channels control input and 1 channel control output from the external control device to the unit s control input or control output terminal For connection of the removable terminal plugs see...

Страница 12: ...ire end back about 7 mm 0 28 When connecting 2 wires or a signal cable to a single terminal crimp them in an insulated twin wire ferrule to prevent their core wires from being separated from one anoth...

Страница 13: ...from this unit to network is muted Audio Settings of speaker volume input volume for individual broadcast classifications and the sensitivity of LINE MIC input for SIP and VMS broadcasting Media Uploa...

Страница 14: ...ts setting it will be necessary to set the PC s network settings so that it can operate on the same network as the IP audio interface Take care that no IP addresses are duplicated in the same network...

Страница 15: ...d down the reset key located on the bottom panel using a pointed tool The speaker automatically restarts and settings initialization begins Tip Clicking on the reset key causes the unit to be restarte...

Страница 16: ...cense s If you need further information about the original open source software including source code please download it from the TOA DATA Library https www toa products com international Please note...