——— PART 2. OPERATING OF CP UNIT AND NO. 200 PROGRAMMING ———
1. PRECAUTIONS FOR INSTALLATION OF CP-66
1. Be careful about damage by static electricity as the CP-66
incorporates CMOS IC's. Do not touch components and connec-
tors.
2. Turn off the AC power switch when you take out or insert the
CP-66 unit, or any other unit.
3. Always insert the CP-66 unit into the "CP" slot. Otherwise,
there is a danger that the unit will be damaged.
4. Make sure mini-jumper for battery back-up is always placed in
ON position each time it is used.
5. Incorrect setting of function select switches may lead to incor-
rect performance.
6. Even if you do not need programming functions, be sure to carry
out initial programming and registration at station No.200 when
you install the new unit. Otherwise, some other functions may
not work properly.
7. The Ni-Cd battery GB50-3FA1 is capable of saving important
memory registration data even at times of power failure.
To keep the battery fully charged, do not cut the power off for
long hours during the first 8 days after new installation. The
CP-66 unit is capable of maintaining the programmed data for
the period of 4 weeks after fully charged even in the event of
long hours of power failure.
(About 4 weeks (25°C), About 8 days (40°C))
Please read following instructions carefully to ensure proper operation of the CP-66
8. We suggest you replace the soldered button batteryGB50-3FA1
(115-42-031 -9) with the new one according to the following list
that shows an expected life span of the battery.
Be sure to make the station No.200 programming after replace-
ment of the battery.
Expected Life Span of small Ni-Cd Battery
Ambient temperature
of exchange
0° C
25° C
40° C
Ambient temperature
of battery
10°C
35° C
50° C
Life span
About 5 years
About 4 years
About 2 years
9. When shipping the CP-66 unit independently, place the mini-
jumper for battery back-up in "OFF" position. Cover the CP
back with cardboard, wrap connector section in aluminium foil
and put it in a conductive bag.
S
s select functions.
n
r #200 Programming
only at time of initial programming of the
n of functions. In this case, station No.200
" but becomes a normal station when switch
.
e system, programming has to be set up in
e becomes the Programming station:
. No. 200 (100)
. No. 470 (400)
. No. 740 (700)
y back-up
1 (3.6V 50mAh)
FUNCTION SELECT SWITCHE
SW-E (1~8)
SW-D (1~8)
SW-C (1 ~ 8)
SW-B (1 ~ 8)
SW-A (1 ~ 8)
-These switche
Link Selectio
PROGRAM SWITCH fo
Set this to"ON"position
exchange and registratio
is "programming sation
is placed in "OFF" position
Note:
In the event of the tie-lin
every exchange.
The first stat ion of each exchang
Exchange "A" . . . . . . . .
Exchange "B" . . . . . . . .
Exchange "C" . . . . . . . .
MINI-JUMPER for batter
Ni-Cd BATTERY GB50-3FA
— 9 —
All manuals and user guides at all-guides.com