SW-A
SW-B
SW-C
SW-D
SW-E
Remarks 1. DIP Switch Positions to Turn out the Same Functions
as the CPU-52A of EXES-5000
Standard Hands-free Intercom System
Place the DIP Switches in the
Positions as follows.
Functions
Link Selection; Link No. 0 ~ 3
Link Selection; Link No. 4 ~ 7
Link Selection; Link No. 8 ~ 11
Link Selection; Link No. 12
~
15
Time Interval Adjustment before Paging
Pre-announcement tone
Switch OFF
Not Activate
Not Activate
Not Activate
Not Activate
None
Switch ON
Activate
Activate
Activate
Activate
1 sec
Conference
Call Transfer, Paging During Normal Call
Priority & Executive Priority
Paging
Secretary Transfer, Group Hunting
System Size Selection
Not Activate
Not Activate
Not Activate
Not Activate
Not Activate
EX-610
Activate
Activate
Activate
Activate
Activate
EX-620
Selectable Numbering Schedules
Emergency All-Call
Paging Priority
Combination Paging
15 Individual Paging Zones
2-Digit Dialing
No.200 (20)~
Not Activate
Not Activate
Not Activate
7 Zones
3 Digit
No. 100 ( 1 0 ) ~
Activate
Activate
Activate
15 Zones
2 Digit
Stations Allowed Access to All Call, Conference
and General Purpose Control
Call Forwarding
Personal Number-Paging/Calling
Group Blocking
Programmable Station Numbering
Pager
Not Activate
Not Activate
P.No.Calling
Not Activate
Not Activate
Not Activate
Activate
Activate
P.No.Paging
Activate
Activate
Activate
Selectable Function Code
Selectable Dial Operation for Paging Response
Output Capacity of General Purpose Control
Memory of Calling Party Indication (Lamp type)
Tone of Called Mode at Privacy Sw. ON
Continuous Calling Tone (No. 200 Programming)
Small
Without memory
Privacy
Not Activate
Large
With memory
Continuous calling
Activate
*1
*1
*1
*1
*1
*1
*1
*2
*3
*4
— 9 —