Toa DX-0808 Скачать руководство пользователя страница 7

(2)  When setting parameters of more than one unit

In this case, use the communications method called "RS-485". Because multiple units are controlled, each

unit  needs its own unique ID registered in advance.  For details, refer to p.8 "8. UNIT ID NUMBER

SETTING". Set the communications port  selection switch in the front  pocket to "RS-485". Connection

between a personal computer and each unit is shown in Fig. 2.

Personal computers normally have only an RS-232C port, and thus require an adaptor to convert the

RS-232C port to an RS-485 port.

Connect the PC's RS-232C port to the DX-0808's female connector for RS-485 communications via the

adaptor. Similarly, make connections for the second  unit and its subsequent units as shown in Fig. 2. Since

the settings made through the PC can  be stored in each unit's memory, the set patterns can be recalled if

only units are connected as shown in Fig. 2'; the adaptor and computer are not necessary to recall the

patterns. In this case, the unit with ID No. 1  acts as a master unit to control the other units.

Fig.2 Communications port connections between a PC and multiple units

(3) When using the DX-0808 in conjunction with the DP-0202 or DP-0204 digital processor

Parameters can be set and controlled from one PC in the same manner and connections as described in

Item (2) above.

7

Содержание DX-0808

Страница 1: ...PAPERS WITH THE APPLIANCE CONTENTS Please followthe instructions in this manual to obtain the optimum results from this unit We also recommend thatyou keepthis manual handyforfuture reference TOA Corp...

Страница 2: ...ng function prevents problems resulting from operator error Wide operating voltage range 90 VAC 250 VAC 3 HANDLING PRECAUTIONS The matrix unit has no parameter setting functions so you use a personal...

Страница 3: ...mp lights functions as a master unit when switching between stored information For details refer to p 8 7 UNIT ID NUMBER SETTING Memory call key MEMORY This key is used to recall the memory pattern se...

Страница 4: ...available unlocked such as memory switching 1 All functions are locked except memory switching 2 All front panel facilities are locked Note Make sure the power is switched ON when you use this switch...

Страница 5: ...p 6 6 PERSONAL COMPUTER CONNECTIONS RS 232C communications port RS 232C A 9 pin D SUB connector for RS 232C communications This connector can only be used when the communications port selection switc...

Страница 6: ...e the communications method called RS 232C Set the communications port selection switch in the front pocket to RS 232C As shown in Fig 1 connect a straight cable from the PC s RS 232C port to the DX 0...

Страница 7: ...C port to the DX 0808 s female connector for RS 485 communications via the adaptor Similarly make connections for the second unit and its subsequent units as shown in Fig 2 Since the settings made thr...

Страница 8: ...lever of the unit ID number setting switch to the right 4 While holding the lever operate the front mounted memory unit number selection key to showthe desired number on the memory unit number displa...

Страница 9: ...al equipment by making the connector s pin No 2 a high level Table 2 shows the relationship of selected memory to each pin s output status Table 2 Selected memory VS pin s output status Note No connec...

Страница 10: ...by expanding its I O buses Use 8 pin DIN connectors for bus connection as shown in Fig 3 Also the internal switch of the unit to be expanded needs to be set Set all internal DIP switches SW 101 SW 102...

Страница 11: ...tor 11 SPECIFICATIONS Specifications are subject to change without notice 0 dB is referenced to 0 775 V RMS Power requirements Matrix configuration Input Output Hum and noise Frequency response Total...

Страница 12: ...12 APPEARANCE TOA Corporation Printed in Japan 133 12 286 4A...

Отзывы: