![Toa C-RM700 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/toa/c-rm700/c-rm700_operating-instructions-manual_1122989038.webp)
38
7.4.14. Sensor alarm
Select "1. ON" to use the Alarm input terminal (such as the C-AL80 and camera alarm).
1. Press the Menu key for 3 seconds or more to display the menu screen.
2. Tilt the joystick up or down to select "SENSOR ALARM," and confirm the selection with the SET key.
The setting will appear on Line 2.
3. Tilt the joystick to the left or right to select either of the following settings, and confirm it with the SET key.
[Setting contents]
S E N S O R
A L A R M
1 . O N
1
1. ON
Uses when receiving alarm signals from the alarm input terminal.
2. OFF
Alarm signals are not received from the alarm input terminal.
7.4.15. Camera alarm
Select "1. ON" to use the Combination camera's alarm contact input.
1. Press the Menu key for 3 seconds or more to display the menu screen.
2. Tilt the joystick up or down to select "CAMERA ALARM," and confirm the selection with the SET key.
The setting will appear on Line 2.
3. Tilt the joystick to the left or right to select either of the following settings, and confirm it with the SET key.
[Setting contents]
C A M E R A
A L A R M
1 . O N
1
1. ON
Uses the Combination camera's alarm contact input.
2. OFF
Does not use the Combination camera's alarm contact input..
Note:
This selection is set to "2. OFF" by the factory.
Note
When alarm settings and alarm report settings are performed on the camera, set the report settings of the
alarm contact number to be used to ON.
Note:
This selection is set to "2. OFF" by the factory.