background image

INSTRUCTION MANUAL

COAXIAL AUDIO ADAPTER

C-AP105

Thank you for purchasing TOA's Coaxial Audio Adapter. Please carefully follow the instructions in this
manual in order to ensure long, trouble-free use of your equipment.

1. SAFETY PRECAUTIONS  .......................... 2
2. LIST OF INCLUDED COMPONENTS

AND PARTS  .............................................. 4

3. GENERAL DESCRIPTION  ........................ 4
4. HANDLING PRECAUTIONS  ..................... 4
5. NOMENCLATURE AND FUNCTIONS

Front Panel  ................................................. 5
Rear Panel  ................................................. 5
Microphone ................................................. 6

6. CONNECTOR WIRING

6.1. Matching cable size 

and stripped cable ends ................ 6

6.2. Cable Connections ............................... 6

7. CONNECTIONS 

7.1. Power Supply Connections .................. 7

7.2. Audio Input Connections ...................... 7
7.3. Audio Output Connections ................... 8
7.4. Speaker Connections ........................... 8
7.5. Contact Input

and Output Connections ................ 8

7.6. AP Line Connections ............................ 9
7.7. Video Equipment Connections ............. 9

8. INSTALLATION 

8.1. Rack-mounting units ............................. 9
8.2. Rack-mounting two units .................... 10
8.3. Wall Mounting ..................................... 10
8.4. Microphone Attachment ..................... 10

9. IF A FAILURE IS DETECTED

(TROUBLESHOOTING) ............. 11

10. SPECIFICATIONS  .................................... 12

TABLE OF CONTENTS

Содержание C-AP105

Страница 1: ...Panel 5 Rear Panel 5 Microphone 6 6 CONNECTOR WIRING 6 1 Matching cable size and stripped cable ends 6 6 2 Cable Connections 6 7 CONNECTIONS 7 1 Power Supply Connections 7 7 2 Audio Input Connections 7 7 3 Audio Output Connections 8 7 4 Speaker Connections 8 7 5 Contact Input and Output Connections 8 7 6 AP Line Connections 9 7 7 Video Equipment Connections 9 8 INSTALLATION 8 1 Rack mounting units...

Страница 2: ...own due to deterioration possibly causing personal injury Also electric shock could result from the unit s exposure to rain Should the following irregularities be found during use immediately switch off the power disconnect the power supply plug from the AC outlet and contact your nearest TOA dealer Do not attempt to further operate the unit to avoid fire or electric shock If you detect smoke or a...

Страница 3: ...ase the user will be required to correct the interference at his own expense Modifications Any modifications made to this device that are not approved by TOA Corporation may void the authority granted to the user by the FCC to operate this equipment C AP105 complies with Part 15 of the FCC Rules Underwriters Laboratories Inc UL has not tested the performance or reliability of the security aspects ...

Страница 4: ...y if Unit A is connected to Unit A or Unit B is connected to Unit B Use relays when controlling equipment that exceeds the unit s contact output capacity of 30V DC 10 mA When permanently installing the Audio Adapter do not place it on equipment that can generate excessive heat over 60 C such as a camera drive or power amplifier 2 LIST OF INCLUDED COMPONENTS AND PARTS Check to be sure that the foll...

Страница 5: ...tween both units 11 Audio Output Terminal Connect a power amplifier to this terminal if the output power of the built in amplifier 1W is insufficient 12 Audio Input Terminal Connects to a MIC or LINE signal level sound source When using an electret condenser microphone short the phantom power supply terminal and the input terminal with a lead wire The phantom power supply specification is 5V 0 2 m...

Страница 6: ... underside of the microphone at the factory Optimal sound input direction 16 17 16 Microphone Used for collecting voice and sound input Microphone sensitivity is the highest in the direction indicated by the arrow in the figure 17 Microphone Mounting Screw for the mounting plate A dedicated mounting screw for the microphone mounting plate which is used to mount the micro phone on a wall or ceiling...

Страница 7: ...PHANT MIC LINE If using an electret condenser microphone C H Lead wire of approx 30mm in length C H PHANT MIC LINE 1 Connect cable conductor to H and shields to C 2 Set the front panel mounted Input level selector switch to the MIC position 3 Adjust the volume control so that voice output is not distorted 1 Connect both the microphone cable conductor HOT and lead wire to H 2 Connect the shields to...

Страница 8: ...bi directional sound output 7 5 Contact Input and Output Connections Contact Inputs Connect to the sensor contact output or switch The C terminal is common to all 4 contact inputs and internally connected to 0 V Contact outputs Connect to equipment s control input These are open collector outputs and the emitter is floated and connected to the C terminal Connect using relays when the control curre...

Страница 9: ...put output terminal The camera s internal microphone or optional external microphone C A10MC cannot be used during camera video operation 8 INSTALLATION When mounting the unit in an equipment rack use the optional mounting bracket set and remove the rubber feet installed on the underside of the unit 8 1 Rack mounting a single unit using the optional MB 15B BK mounting bracket set C AP105 Rack moun...

Страница 10: ...one Attachment Mounting to a wall or ceiling 1 Remove the microphone mounting screw for the mounting plate 17 and detach the microphone mounting plate Note Removing the mounting screw 17 disassembles the microphone Take care not to drop its parts and components 2 Using the 2 supplied plate mounting screws mount the microphone mounting plate removed in Step 1 to a wall or ceiling 3 Using the microp...

Страница 11: ...ations cannot be performed while the indicator remains off Phantom power supply is not connected to the electret condenser microphone in use The polarity and terminals of the audio input and speaker output are not correctly connected Input level is not adjusted The Contact status indicator is not illuminated Communications cannot be performed while the indicator remains off The contact input of an...

Страница 12: ...stance under 200Ω short circuit current 5 mA Removable terminal block 8P 4 contacts open collector output withstand voltage 30V DC current max 10 mA Removable terminal block 8P 10ºC to 50 C Under 90 RH no condensation Panel Pre coated steel plate black Munsel N1 0 30 gloss Cover Pre coated steel plate black Munsel N1 0 30 gloss 210 W x 47 4 H x 126 5 D mm 2 815 g 2 Power Source Power Consumption C...

Отзывы: