18
7.2. Optional Modules
7.2.1. D-001T (2-Channel Input Module)
Hot
Cold
Earth
Hot
Cold
Earth
1
2
D-001T
1
7.2.2. T-001T (Audio Output Expansion Module)
Hot
Cold
Earth
Hot
Cold
Earth
1
2
T-001T
2
1. Monaural input terminals [1, 2]
Electronically-balanced 3P removable terminal blocks.
Input level: –60 dB to –10 dB selectable.
Input impedance is 10 k
Ω
when the phantom power is OFF, and
3 k
Ω
when ON.
2. Monaural output terminals [1, 2]
Electronically-balanced 3P removable terminal blocks.
Output level:
0 dB
Output impedance: 600
Ω
For unbalanced connection, connect the unit's Hot and Earth
terminals to the connected equipment's Signal and GND
terminals, respectively. (Keep the unit's Cold terminal free.)
The D-001T module is designed for use with the 9000 Series amplifiers.
Up to 4 modules (8 channels in total) can be inserted into the amplifier.
The module can handle signals ranging from microphone level (–60 dB) to line level (–10 dB) in 9 input
sensitivity levels.
Phantom power (24 V) can be supplied for microphone level (–60 dB to –30 dB) signals.
The D-001T module has an internal digital signal processor that can process input signals.
The D-001T module is required to use a VOX (Voice Operated Exchange) function and input channel level
meter.
The T-001T module is designed for use with the 9000 Series amplifiers and can expand 2 output channels per
module.
Since the main unit has 2 fixed outputs, the audio output can be expanded to 8 channels by using a maximum
of 3 modules (6 channels).