![Toa A-5000 Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/toa/a-5000-series/a-5000-series_software-instructions_1122182033.webp)
33
10.5.3. Deleting edited Contents without Storing them in preset Memory
When wishing to return the parameters edited in the Flow View back to those currently stored, delete the edit.
Note: Once the edit contents have been deleted, they cannot be restored.
Step 1. Click the preset memory number/name button in the Memory View.
Memory List panel is displayed.
[Memory List panel]
The currently selected Preset Memory button is displayed in orange.
Step 2. Click the [Trash] button.
After the edited contents are deleted, the parameters stored before the edit are called up.
1
11. CoMMUNICatIoN SettINGS
11.1. Connections between the pC and the Unit
Connect the unit’s LAN terminal to the PC via a switching hub.
Connect a PC and the unit to a switching hub using LAN straight-through cables individually.
PC with the A-5000 PC
Software installed
LAN terminal
Switching hub
Category 5 or higher shielded twisted
pair straight-through cable for LAN
(with RJ45 connectors)
A-5006/5012
11.2. Method to enable Communications between the pC and the Unit
Step 1. Perform network settings by selecting [Network Connection Settings] from the menu view.
the next page “Connection Settings.”
Step 2. Make Communications by selecting [Network Connect] from the menu view.