6. General Functions 

 

 

 

 

(1) Zero function 

Use to correct drifted zero value when the scale is unloaded, and motion is 
not  detected.  This  function  works  when 

ZERO  KEY

  is  pressed,  and  the 

ZERO LAMP

 is on. 

 

(2) Setting tare weight function. 

Press the 

TARE KEY

. Then, the scale will memorize the weight of the tare 

and will display zero v

alue ‘0’kg. The 

TARE LAMP 

will be on. 

    To escape this function, remove everything from the scale, and press the 

TARE or ZERO KEY

Then, the 

TARE LAMP

 will be off and this function is terminated. 

 

(3) Hold function 

Automatic hold function 

■ Press 

HOLD KEY

 when the scale is empty (Initial zero state). 

■ The weight display will indicate 

AH ON

HOLD LAMP

 is on. 

■ After loading a thing, if the weight turns stable then, a display shows 

-----

 

and average weight will appear. 

 

■ The weight of a loaded thing is displayed. 
■ To escape the automatic hold mode, when zero point is on, press 

HOLD   

KEY

    Then,  the  message  of 

AHOFF

  is  displayed  and 

HOLD  LAMP

  is  off  and 

normal weighing mode is reverted. 

 

Manual hold function

 

■ Press 

HOLD KEY

 loading a thing. 

■ This message of 

HOLD

 is displayed and sequentially the message of 

-----

 

is shown with appearing the average weight.   

■ The weight of a loaded thing is displayed. 
■ To escape the manual hold mode, remove everything from a hook, or   

press  the 

HOLD  KEY

.  Then, 

HOLD  LAMP

  will  be  off  and  the  scale 

changes from a hold mode to a normal mode. 

 

 

Содержание TCB Series

Страница 1: ... 1 TCB L SERIES VER 101 CRANE SCALE OPERATIONAL MANUAL ...

Страница 2: ...f there are any questions such as wrong or missing parts of the contents listed in this manual please contact us 4 To improve the product performance functions can be changed with no notice 5 Please understand that TMT does not have responsibility for a demand related to loss lost profit etc caused by operating the product regardless of the third clause ...

Страница 3: ...iption of Panels and Symbols 7 5 Rechargeable Battery 8 6 General Functions for Weighing Mode 9 7 Setting Mode 10 8 Test Mode 15 9 IR Remote Controller 17 10 ZigBee Wireless Option 1 18 11 Bluetooth Wireless Option 2 18 12 Real Time Clock Option 1 19 13 Check Message 20 ...

Страница 4: ...oduct in a dry place Do not use the product in a place with strong direct sunlight and dust Do not use the product in a place with severe vibration Check the supply voltage Please check if the safety hook is connected well before you install our TCB L so that the SHACKLE is not separated 2 Main Features Swivel hook Big size display Easy to exchange battery pack Li Po battery Standard IR remote con...

Страница 5: ...verall view Dimensions MODEL Max kg e d kg Weight kg DIMMENSION UNIT mm H A W B TCB 1T L 1 000 0 5 8 9 407 62 50 25 TCB 3T L 3 000 1 15 2 525 73 57 34 TCB 5T L 5 000 2 16 7 525 73 57 40 TCB 10T L 10 000 5 26 9 697 101 83 55 ...

Страница 6: ...aptor 12V 1A 5V 1A Display lamp Low battery Zero Tare Hold Stable Function ON OFF Zero Tare HOLD Temperature 20 60 Max tare weight Full Tare Safety overload 150 of capacity Zero point Within 2 of Maximum Weight Initial zero band Within 10 of Maximum Weight Parts Infrared controller Power adaptor Manual Parts Rechargeable adaptor Crane scale Infrared remote controller ...

Страница 7: ...n the tare is included b Indicates when the hold function is set r Indicates when a battery has to be recharged B type q Indicates when the ZigBee communicates data L type Keypad Key Description ON OFF Power ON OFF of indicator ZERO The key to make weight value as zero TARE The key to perform tare weight HOLD The key to measure the unstable weight ENTER The key to store confirm setting value ...

Страница 8: ...ording to battery condition Clamp 2 Method of exchange battery pack Turn clamps that exit on both sides of charger to the right in a quarter Pull out a battery pack Inserting is in reverse 3 Battery pack specifications Nominal capacity 4000mAH Nominal voltage FND Type 7 4V LCD Type 3 7V 4 Low battery lamp In order to prevent the electric discharge after LOW BATTERY LAMP is on the power will be tur...

Страница 9: ...e scale is empty Initial zero state The weight display will indicate AH ON HOLD LAMP is on After loading a thing if the weight turns stable then a display shows and average weight will appear The weight of a loaded thing is displayed To escape the automatic hold mode when zero point is on press HOLD KEY Then the message of AHOFF is displayed and HOLD LAMP is off and normal weighing mode is reverte...

Страница 10: ...he left or right by one place Used to increase the setting constant one by one Used to save the value and to move next menu 3 Menu F01 Adjustment the speed of weight change 1 9 Setting Menu Description F01 1 Very fast F01 5 Normal F01 9 Very slow F02 Weight backup 0 1 Setting Menu Description F02 0 Not used F02 1 Used F03 Stable condition set of weight 1 9 Setting Menu Description F03 1 Sensitive ...

Страница 11: ...Description F05 1 Very fast F05 5 Normal F05 9 Very slow F06 Auto Hold Start 0 1 Setting Menu Description F06 0 Manual F06 1 Automatic F07 Initialization Hold Weight 1 9 Setting Menu Description F07 0 Zero 0 F07 3 Below 3 division F07 9 Below 9 division F08 Function key 0 3 Setting Menu Description F08 0 FND Type Not used LCD Type Back light ON OFF F08 1 Print command key F08 2 18byes weighing dat...

Страница 12: ...ghing data by automatically at HOLD Please select this mode if you used the wireless printer In case of F10 2 4 the print form data refer to F11 is send to printer and printer is printing with the print form At this time the printer mode of YJ380T must change to the NORMAL MODE In case of F10 3 5 the 18bytes wireless data is send to printer and printer is printing with the itself format At this ti...

Страница 13: ...d Weighing data 8bytes a 13 5 kg 1 3 5 b 135 kg 1 3 5 CR 0x0D LF 0x0A F11 Print form 0 2 Setting Menu Description F11 0 Form 0 Date and time serial No Item No weight F11 1 Form 1 Date and time weigh No Item No weight The serial number is not saved FORM 0 FORM 1 2013 10 13 12 00 012 ID_9 131 kg F12 Print line feed 0 9 Setting Menu Description F12 0 1 line feed after printing F12 5 6 line feed after...

Страница 14: ...n F14 0 Not used F14 1 ZigBee communicate with TD series TF100 and TF400 F14 2 ZigBee communicate with TF200 dongle F14 3 Bluetooth communicate with smartphone In case of F14 2 refer to the 18bytes data format In case of F14 3 F10 function can t use F15 Back light mode LCD type 0 2 Setting Menu Description F15 0 Manual ON OFF F15 1 Automatic ON OFF Weighing ON Zero OFF F15 2 Always ON F16 Back lig...

Страница 15: ...t you want to test the key number is appeared on the display If press ENTER KEY moves into next menu TARE 2 HOLD 3 ENTER 4 TEST 3 A D conversion test Load cell test Display Description 2072 The value is the conversion constant for A D The value may be different according to scale models If press ENTER KEY move into next menu Please check if the displayed number is easily changed with giving force ...

Страница 16: ... 16 TEST 4 Back light test LCD Type Display Description LIGHT If you press the ZERO KEY once back light turns on and once again back light is turns OFF If press ENTER KEY move into weighing mode ...

Страница 17: ...board CLEAR Same as scale keyboard SUM Use to add weights If press a SUM KEY the sum of weights is displayed After that about 2 sec later a weighing mode is reverted Weight of less than 5 digits is not summed Maximum of sum weights is 99999 and if it exceeds the weights is initialized to 0 Type Infrared Available Distance 6 m 10 m Available Angle 60 Power 3V 1 5V AA 2 EA ...

Страница 18: ...0dBm RF In out impedance 50 ohm TXRF RXRF Spurious 2nd harmonics 30dBm Radio link effective range Approx 100M Open space 11 Bluetooth Wireless Option 2 The OP 02 is communicates with smart phone Bluetooth specification Fully qualified with Bluetooth v2 0 EDR specification EDR Enhanced data rate compliant with v2 0 of specification for both 2Mbps and 3Mbps RF frequency range 2401 2480 MHz Output po...

Страница 19: ... KEY 2 Keyboard Used to move the input value to the left or right by one place Used to increase the setting constant one by one Used to save the value and to move next menu 3 Menu No Display Description 1 YEAR 2013 Modify the year 2 DATE 10 13 Modify the date 3 TIME 18 00 Modify the time 4 END The end ...

Страница 20: ... Something wrong in a Load cell connection or in an A D conversion Please contact us to resolve this technical problem When a thing is over weighed within the maximum weight value the error message is displayed Do not weigh the thing whose the limit of a maximum weight value is exceeded If a load cell is broken then the load cell has to be replaced ...

Страница 21: ... 21 MEMO ...

Отзывы: