Version-01
Cal.VJ76B
Cal.VJ76B watch assembly notice points
Note:
・
Before a Dial set, confirm the positions of First date indicator and Second date indicator.
・
Before date setting, confirm the positions of holes in 1 o'clock position.
Holes position checkpoint
First date indicator (The single numeral)
Second date indicator (The Tens' numeral)
・
When the holes are not in right position, do the following procedure.
< position setting method >
1.First date indicator position setting.
・
To unify the First date disc's notch with main plate notch on edge at 9 o'clock.
(Pull out the crown to first click and turn the crown to set First date indicator.)
main plate
First date disc's notch
2.Second date indicator position setting.
Rotate the Second date indicator in clockwise by touching on its surface lightly with finger.
Until the Second date indicator hole overlap with the First date indicator hole
at 1 o'colock position. The position is set.
(NOTE)
Second date indicator cannot be turned except the status showed in Fig 5.
Please beware not to turn the disc after the positions had been set, otherwise the date cannot be display properly.
OPERATION
10
Enlargement
Touching on its
surface lightly
with finger.
(Clockwise)
Fig.5