TMG DFP10 Скачать руководство пользователя страница 9

DANGER!

Be certain the power switch is “OFF” prior to connecting the battery clamps / power cables to the

power source or installing the cable into the pump to prevent unexpected starting of the motor. Unexpected

motor start can cause unintended discharge of fuel, creating an explosion and / or fire hazard.

WARNING!

The pump body can become hot with extended use. Always use the handle to lift and carry the

pump when moving it. Use caution when gripping the handle as exposed skin may be burned if it contacts a

hot pump.

IMPORTANT!

The RD series pump uses thermal overload protection to prevent overheating. If the pump

shuts off due to thermal overload, turn the power switch “OFF”. Once the pump cools the switch can be set

to “ON” again to reset the thermal protection.

WARNING!

Use caution when operating or carrying the pump. The hoses and electrical power cable can

be a trip hazard; caution should be exercised any time the pump is moved with the hoses and power cable

connected to avoid tripping or entanglement.

CAUTION! DO NOT

operate the pump dry for more than 30 seconds.

DO NOT

operate the pump in bypass

more than 5 minutes. Damage to the pump will occur.

Power Switch

The pump features a sliding ON / OFF power switch. The switch is located on top of the pump at the back of the

pump housing. To operate the pump, push the switch to the desired position. Push “ON” to operate the pump, and push

“OFF” to turn the pump off.

NOTE:

The side where the switch button is depressed is the function the switch is performing.

Operational Safety

WARNING!

Pump assembly can become hot with extended use. Use caution when handling the pump after

use; always use the handle to move or hold the pump. Pump has 30 minute on / 30 minute off duty cycle.

CAUTION! DO NOT

operate the pump if any part of the explosion proof motor construction is missing or

compromised. Disassembly of the motor will compromise the explosion proof design and void any warranty.

WARNING! NEVER

disconnect the power cable from the pump while pump is switched on or connected to a

power source.

ALWAYS

switch the pump off and disconnect all the clamps from the power source

PRIOR

to disconnecting the power cable from the pump. Electrical shorts, sparks, or unexpected start up canoccur.

DANGER! DO NOT

use pump in enclosed areas when pumping hazardous or explosive fluids. Pumping

area should be well ventilated. Concentrated vapors in an enclosed area are noxious and highly explosive!

Pump OFF

Pump ON

WWW.TMGINDUSTRIAL.COM

P09/20

Toll Free:1-877-761-2819

Содержание DFP10

Страница 1: ...r other protective gears while in assembly Missing parts or questions on assembly Please call 1 877 761 2819 or email cs tmgindustrial com Do not return the product to dealer they are not equipped to...

Страница 2: ...ations 5 Pump Installation 6 MountingFoot and NozzleBootInstallation 4 Suction Hose Configuration 7 FuelingSafety 4 DC Power Connection 5 Power Switch 6 Operational Safety 6 Troubleshooting 7 Technica...

Страница 3: ...of the portable pump Your product comes with over 10 years of pump manufacturing experience behind it providing you the value that comes with superior performance user friendly design outstanding dur...

Страница 4: ...s Leaking fuel may cause the potential for fire and explosion CAUTION This product is not suited for use with fluids intended for human consumption or fluids containing water Materials of construction...

Страница 5: ...mp for your convenience and safety Each kits is equipped with 1 Hose reel with 49 hose 2 Automatic gun 3 Automatic gun base 4 Automatic gun holder 5 Hose reel base 6 12V DC motor 7 Connector hose WWW...

Страница 6: ...olled movement resulting in damage injury death and potential fire or explosion Pump Installation The pump is designed to be portable for your convenience and safety It features a unique hinged vane d...

Страница 7: ...rated to at least 50 psi 2 Reconfigure inlet and outlet flanges if necessary optional Instructions below 3 Use a conductive nozzle or valve at the end of the discharge hose that can be shut off tight...

Страница 8: ...Install power cable by aligning flat on plug with front of pump HAND TIGHTEN ONLY The power cable terminates in black and red clamps All two clamps must be used 1 Connect the black negative clamp to...

Страница 9: ...occur Power Switch The pump features a sliding ON OFF power switch The switch is located on top of the pump at the back of the pump housing To operate the pump push the switch to the desired position...

Страница 10: ...rizontal distance from pump to liquid Power connections reversed Correct power connections Low capacity Excessive dirt in screen Remove and clean screen Suction line problem Check suction line for lea...

Страница 11: ...ower Switch failure Return to place of purchase Incorrect or loose wiring Check wiring connections Motor inoperative No power Check incoming power Switch failure Return to place of purchase Motor fail...

Страница 12: ...m gear vane Rotary Hinged Vane Flow Rate with supplied hose nozzle Up to 10 GPM Flow Rate open flow no hose or nozzle Up to 15 GPM Max discharge pressure 16 PSI Head Max ft 20 Max suction ft 10 Inlet...

Страница 13: ...uipment and do not use this equipment for a purpose for which it was not intended 5 Use proper eye protection when assembling and using the kit 6 Check for damaged parts Before using this product care...

Страница 14: ...every half revolution of the drum 2 To latch the reel pull out the hose and allow it to retract after hearing the first second or third click 2 ADJUSTMENTS FOR HOSE REEL 1 Adjusting spring tension If...

Страница 15: ...ing Install stopper on working end of hose if required 3 Disengage latch paw land allow hose tore tract 4 Replacing the swivel 1 If the swivel leak replace the O ring or seal 19 and washer 18 by remov...

Страница 16: ...ion Qty Ref Description Qty 1 Hose reel 1 6 Hose reel base 1 2 Automatic gun 1 7 Fuel pump base 1 3 Elbow 1 8 Motor 12V DC 1 4 Automatic gun base 1 9 Connector hose 1 5 Automatic gun holder 1 WWW TMGI...

Страница 17: ...FEUL PUMP WWW TMGINDUSTRIAL COM P17 20 Toll Free 1 877 761 2819...

Страница 18: ...urance box 1 5 Pump body 1 19 Rear cover 1 6 Base 1 20 Switch 1 7 Leaf blade rotor 5 21 Tightening nut 1 8 Leaf blade 1 22 Positioning set 1 9 O loops 1 23 Lock the nut 1 10 Pump cover 1 24 Two phase...

Страница 19: ...HOSE REEL WWW TMGINDUSTRIAL COM P19 20 Toll Free 1 877 761 2819...

Страница 20: ...d screws M5X55 2 14 Hexagon anti loosening nut M6 14 42 Bearing 15 Right Block 1 43 Exit bracket 1 16 Ratchet wheel 1 44 Gasket 16 1 17 Body 1 45 Cover nut M16 1 18 High and low lip seal ring 16 24 6...

Отзывы: