DANGER!

Electrical wiring should be performed with extreme caution and in compliance with local,

state, and national electrical code NEC/ANSI/NFPA 70, NFPA 30, and NFPA 30A, as appropriate for the

intended use of the pump. Threaded rigid conduit, sealed fittings, and conductor seal should be used

where applicable. The pump must be properly grounded. If installing in deviation of this manual, a licensed

electrician must perform the installation. Improper installation or use of this product will result in serious

bodily injury, or death!

DANGER!

To ensure safe and proper operation of your equipment, it is critical to read and adhere to all of

the following safety warnings and precautions. Failure to follow instructions below, improper installation, or

use of this product, will cause serious bodily injury or death!

NEVER

smoke near the pump, or use the pump near open flames when pumping a flammable liquid!

Fire can result!

This product shall not be used to transfer fluids into any type of aircraft due to spark / static discharge

possibility. Spark / static discharge will cause explosions.

WARNING!

Threaded pipe joints and connections should be sealed with the appropriate sealant or sealant

tape to minimize the possibility of leaks. Leaking fuel may cause the potential for fire and explosion.

CAUTION!

This product is not suited for use with fluids intended for human consumption or fluids

containing water. Materials of construction are not food grade. The pump is water tolerant, however,

extended use with water will shorten the life of the vanes, and can cause swelling of the rotor. Flush / drain

the pump after pumping water to be certain water does not stand in the pump body to prevent premature

wear. Flush with a petroleum product (gasoline, diesel, light oil, etc) to eradicate residual water.

IMPORTANT!

A Fill-Rite Filter should be used on the pump outlet to ensure no foreign material is

transferred to the fuel tank. Foreign material can damage the equipment being fueled.

Safety Information

DANGER!

To minimize static electricity build up and possible explosion, use only static wire conductive

hose when pumping flammable fluids, and keep the fill nozzle in contact with the container being filled

during the filling process. Spark / static discharge will cause explosions.

CAUTION!

The pump motor is equipped with thermal overload protection; if overheated, the motor will

shut off to prevent damage to the windings. If this happens, you must turn off the pump power to reset this

safety feature, and turn the pump back on when it has cooled to continue use. The pump will not restart

until properly cooled.

WWW.TMGINDUSTRIAL.COM

P04/20

Toll Free:1-877-761-2819

Содержание DFP10

Страница 1: ...r other protective gears while in assembly Missing parts or questions on assembly Please call 1 877 761 2819 or email cs tmgindustrial com Do not return the product to dealer they are not equipped to...

Страница 2: ...ations 5 Pump Installation 6 MountingFoot and NozzleBootInstallation 4 Suction Hose Configuration 7 FuelingSafety 4 DC Power Connection 5 Power Switch 6 Operational Safety 6 Troubleshooting 7 Technica...

Страница 3: ...of the portable pump Your product comes with over 10 years of pump manufacturing experience behind it providing you the value that comes with superior performance user friendly design outstanding dur...

Страница 4: ...s Leaking fuel may cause the potential for fire and explosion CAUTION This product is not suited for use with fluids intended for human consumption or fluids containing water Materials of construction...

Страница 5: ...mp for your convenience and safety Each kits is equipped with 1 Hose reel with 49 hose 2 Automatic gun 3 Automatic gun base 4 Automatic gun holder 5 Hose reel base 6 12V DC motor 7 Connector hose WWW...

Страница 6: ...olled movement resulting in damage injury death and potential fire or explosion Pump Installation The pump is designed to be portable for your convenience and safety It features a unique hinged vane d...

Страница 7: ...rated to at least 50 psi 2 Reconfigure inlet and outlet flanges if necessary optional Instructions below 3 Use a conductive nozzle or valve at the end of the discharge hose that can be shut off tight...

Страница 8: ...Install power cable by aligning flat on plug with front of pump HAND TIGHTEN ONLY The power cable terminates in black and red clamps All two clamps must be used 1 Connect the black negative clamp to...

Страница 9: ...occur Power Switch The pump features a sliding ON OFF power switch The switch is located on top of the pump at the back of the pump housing To operate the pump push the switch to the desired position...

Страница 10: ...rizontal distance from pump to liquid Power connections reversed Correct power connections Low capacity Excessive dirt in screen Remove and clean screen Suction line problem Check suction line for lea...

Страница 11: ...ower Switch failure Return to place of purchase Incorrect or loose wiring Check wiring connections Motor inoperative No power Check incoming power Switch failure Return to place of purchase Motor fail...

Страница 12: ...m gear vane Rotary Hinged Vane Flow Rate with supplied hose nozzle Up to 10 GPM Flow Rate open flow no hose or nozzle Up to 15 GPM Max discharge pressure 16 PSI Head Max ft 20 Max suction ft 10 Inlet...

Страница 13: ...uipment and do not use this equipment for a purpose for which it was not intended 5 Use proper eye protection when assembling and using the kit 6 Check for damaged parts Before using this product care...

Страница 14: ...every half revolution of the drum 2 To latch the reel pull out the hose and allow it to retract after hearing the first second or third click 2 ADJUSTMENTS FOR HOSE REEL 1 Adjusting spring tension If...

Страница 15: ...ing Install stopper on working end of hose if required 3 Disengage latch paw land allow hose tore tract 4 Replacing the swivel 1 If the swivel leak replace the O ring or seal 19 and washer 18 by remov...

Страница 16: ...ion Qty Ref Description Qty 1 Hose reel 1 6 Hose reel base 1 2 Automatic gun 1 7 Fuel pump base 1 3 Elbow 1 8 Motor 12V DC 1 4 Automatic gun base 1 9 Connector hose 1 5 Automatic gun holder 1 WWW TMGI...

Страница 17: ...FEUL PUMP WWW TMGINDUSTRIAL COM P17 20 Toll Free 1 877 761 2819...

Страница 18: ...urance box 1 5 Pump body 1 19 Rear cover 1 6 Base 1 20 Switch 1 7 Leaf blade rotor 5 21 Tightening nut 1 8 Leaf blade 1 22 Positioning set 1 9 O loops 1 23 Lock the nut 1 10 Pump cover 1 24 Two phase...

Страница 19: ...HOSE REEL WWW TMGINDUSTRIAL COM P19 20 Toll Free 1 877 761 2819...

Страница 20: ...d screws M5X55 2 14 Hexagon anti loosening nut M6 14 42 Bearing 15 Right Block 1 43 Exit bracket 1 16 Ratchet wheel 1 44 Gasket 16 1 17 Body 1 45 Cover nut M16 1 18 High and low lip seal ring 16 24 6...

Отзывы: