GB - 11 [email protected]
GB - 12 [email protected]
Model: MZ-VDP-NE202
V
C
C
A
U
D
IO
G
N
D
V
ID
E
O
MONITOR2
MONITOR1
NO
V
C
C
A
U
D
IO
G
N
D
V
ID
E
O
SPK(VOL)
NC
Independent power interface for doorbell (12V) ---optional
If the distance is too long and not provide enough power to
unlock the door opener, you can add this independent power
supply (12V) for the doorbell separately.
Electric mortise lock
Magnetic lock
Cathode lock
NC Lock
Electronic lock
NO Lock
1) Mode to add RFID card:
In standby mode, short press the
setting button, enter the mode to add
RFID card, swipe RFID card in the card
swiping area, you can add a card, you can
Repeat the RFID card to add more RFID
cards, and then press the set button to
exit the mode to add RFID card.
2) Reset mode: In standby mode,
press and hold the setting button for
3 seconds to enter reset mode, then
press the setting button three times,
you will hear a sound, all card numbers
will be deleted, and it will return to
standby mode.
a
Setting button: Add card mode
or Reset mode
GND
Lock-V+
Power supply control
Pulse electric lock
Cathode lock
LOCKTime
2S-10S
DOOR
EXIT
NO
COM
COM
CONTROL-
Push
GND
12V
COM
NC
NO
Magnetic lock
Pulse electric
lock
Exit Button
Unlock Time
(2S-10S)
SPK
(VOL)
NC
COM
NO
COM
SET
Status LED
indicator
Model: MZ-VDP-NA262F
Indoor
monitor
1.Red:VCC
2.White:Audio
3.Black:GND
4.Yellow:Video
1. Type A: NC+COM, it requires extra power supply for the lock itself only
2. Type B: NO+COM, it requires extra power supply for the lock itself only
3. Type C: For long distance connection between the monitor and the outdoor station,
in case outdoor station can not get enough power from the monitor for normal working,
it is suggested to provide DC12V power supply to the Power-In terminal, here the doorlock
itself does not need extra power supply.
A: NC+COM
B: NO+COM
C: Electric lock
Independent power interface for doorbell (12V) ---optional
If the distance is too long and not provide enough power to unlock the door opener,
you can add this independent power supply (12V) for the doorbell separately.
4. Reset to factory setting: In standby mode, press and hold the setting button for 3 seconds
to enter reset mode, then press the setting button three times, you will hear a sound, all
configurations of RFID cards, fingerprints and password will be deleted, the doorbell will
return to standby mode.
DOOR
EXIT
Power supply control
NO
COM
COM
NC
NO
NC Lock
NO Lock
Electronic lock
Electric mortise lock
Magnetic lock
Cathode lock
CONTROL-
Push
GND
12V
COM
NC
NO