![TMB ProPlex 6-Track Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/tmb/proplex-6-track/proplex-6-track_quick-start-manual_1121649008.webp)
LED error indications
If one of the LEDs glows pink (magenta) and remaining LEDs glow red, it indicates that:
1. There is no SD card inserted.
2. Write protection is active
3. File format saved on the SD card is not the correct file format.
Multiple LED indicators
1. If no memory card inserted, LED 1 will glow pink (magenta) and LEDs 2 to 5 will flash
red. Inserting the SD card will not change the LED status. To correct the error, reboot
the 6-Track by unplugging from the power source and plugging back in.
2. Write protection is active if LED 3 glows magenta and other LEDs flash red. In this state
it is possible to read the scenes, but not write new ones. Write protection can be
accessed manually on the SD cards by sliding LOCK/UNLOCK switch to unlock.
3. Scenes saved on the memory card must be in FAT32 file format. If the scenes are saved
in a different format, the device will recognize them as non-readable and LED 4 will light
up magenta and remaining LEDs will flash red. This indication occurs whenever there is
a problem with the scene file format.
SD card formatting
To format the SD card:
Press REC and scene button number six at the same time, while plugging in the power.
If the
power is not plugged in at the same time while holding the two buttons, the process will not
commence. After formatting, the second LED will illuminate, indicating that the process has ended
successfully.
Note! Formatting the SD card will cause user settings to be erased and device will create
new config.cfg file with default factory settings.
Software upgrade
To upgrade the software:
Press first and second buttons simultaneously while plugging in the power.