background image

Battery and charging

 

 

The device has a 1100mAh Li-ion battery that can be charged by using the Micro 
USB cable. When device is charging, a red LED will turn ON. 
 
Battery indicator states: 

 

When battery charge is 

full (100%), the battery 

indicator on the LCD 

screen will be green

 

When battery charge is 

below 50%, the battery 

indicator on the LCD 

screen will be orange and 

show less than half-full. 

When the battery is almost 

empty, the battery 

indicator on the LCD 

screen will turn red in 

color.  

 

 

 

 

 

Software updates 

 

Software updates are done via a micro usb cable and a pc. In the event you need to 
update the HHP software, please contact TMB tech support. 
 
 

Frequently Asked Questions

 

 

What is the purpose of the DMX port?

 

The DMX port is designed to output test patterns to IMS Universe Drives for lamp 
string testing purposes. Instead of testing one lamp, the user can test whole lamp 
string. 
 

What can I do with micro USB port?

 

The HHP is charged through the micro USB port. Software updates can also be done 
through micro USB port. 
 

I get a “lamp error” message. What shall I do? 

There is a problem with the lamp connected to the HHP. First, visually inspect the 
lamp, followed by a physical shake of the lamp to ensure there are no internal parts 
are loose. If there is a problem with a lamp or multiple lamps on a string, please 
contact  TMB Tech support for troubleshooting tips (see contact info on last page). 
 

"Test lamps" test shows different shows colors beyond the lamp’s capability. 

 

This happens when the user has selected wrong "patch" type for the lamp used with 
HHP. Solution: change lamp test to match lamp type connected. 
 

Can I test more than 1 lamp? 

A DMX port has been added to connect the HHP to an IMS universe drive to test the 
whole lamp string. 

 

 

Содержание IMS Mk2

Страница 1: ...MS Mk2 Hand Held Programmer User Guide TMB 24 7 Technical Support US Canada 1 818 794 1286 Toll Free 1 877 862 3833 877 TMB DUDE UK 44 0 20 8574 9739 Toll Free 0800 652 5418 e mail techsupport tmb com...

Страница 2: ...EEN Green color test BLUE Blue color test WHITE White color test R G Red green color test R B Red blue color test R W Red white color test G B Green blue color test G W Green white color test B W Blue...

Страница 3: ...fter which the Hand Held Programmer will power off 0 10 0 never 1 10 time in minutes Volume Set the volume level 0 7 0 mute 1 7 higher the number higher the volume About Information about software ver...

Страница 4: ...e need arises for lamp readdressing and replacement the IMS HHP is a convenient powerful and portable tool 2 Testing the IMS lamps The HHP can test all IMS lamps as well as output a test sequence to a...

Страница 5: ...onfirm the selection Set DMX address submenu This submenu is for setting the DMX address of a connected IMS Lamp If no lamp is connected to the HHP screen with NO LAMP notification will appear Connect...

Страница 6: ...number in the lamp chain useful for quick addressing by the nth lamp 3 Software version that will be uploaded to lamp 4 Mode that will be patched in the lamp 5 DMX address that will be programmed in...

Страница 7: ...ck a notification sound if the volume setting is set at 1 or higher Confirmation of a successful lamp programming shows the DMX address changed to the programmed address and next incremental address w...

Страница 8: ...ynamic White LED lamps connected Three lamps are shown Dynamic white lamps have a two DMX channel footprint Warm White Clear Filament LED lamps connected 3 lamps are shown Warm White Clear filament la...

Страница 9: ...RGB W LED lamps connected 3 lamps are shown RGBW W lamps have a 4 DMX channel footprint Example for mixed LED lamps 1 RGB white 2 Warm White Clear Filament 3 Dynamic White...

Страница 10: ...The time can be changed by using the UP and DOWN buttons When the desired time has been chosen press the SELECT button to store the new setting To return to the previous menu without making changes pr...

Страница 11: ...has been chosen press the SELECT button to store the setting To return to the previous menu without making changes press ESCAPE button Value Reaction 0 The HHP will not make any sound 1 7 Higher the n...

Страница 12: ...tring testing purposes The user can change the lamp and type using the UP and DOWN buttons When the required lamp has been chosen press the SELECT button to activate the setting To return to previous...

Страница 13: ...amps at the same time Lamp OFF Red Green Blue White R G red green R B red blue R W red white G B green blue G W green white B W blue white R G B red green blue G B W green blue white R G W red green w...

Страница 14: ...verse Drives for lamp string testing purposes Instead of testing one lamp the user can test whole lamp string What can I do with micro USB port The HHP is charged through the micro USB port Software u...

Страница 15: ...nstead of using the DMX address 5 which would have a sequence number in chain 2 the user sets the DMX address 6 and this results with symbols as it is unknown which device it is in the lamp sequence T...

Отзывы: